![BTI 9 049 759 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/bti/9-049-759/9-049-759_original-instructions-manual_2825115025.webp)
English |
25
2 609 140 980 • 10.12.12
Pay attention that battery indicator
h
indicates at
least 1/3 capacity:
Hold the measuring tool in such a manner that
the type plate
13
faces toward the ground. Avoid
bright light sources or direct sunlight from shin-
ing on the area
12
and
13
, without covering off
this area.
– Press and hold buttons
5
and
7
until the illumi-
nated ring
1
lights up red. Then release both but-
tons.
– When the calibration was successful, the meas-
uring tool will automatically start after a few sec-
onds, and will be ready for operation again.
Note:
If the measuring tool does not automatically
start, repeat the recalibration. If the measuring tool
still does not start, send it in the provided protec-
tive pouch to an authorised customer services
agent.
Maintenance and Service
Maintenance and Cleaning
Check the measuring tool each time before
use.
In case of visible damage or loose compo-
nents inside the measuring tool, safe function
can no longer be ensured.
Keep the measuring tool clean and dry at all times
to ensure proper and safe working.
Do not immerse the measuring tool in water or
other fluids.
Wipe away debris or contamination with a dry, soft
cloth. Do not use cleaning agents or solvents.
In order not to affect the measuring function, de-
cals/stickers or name plates, especially metal
ones, may not be attached in the sensor area
12
on
the front or back side of the measuring tool.
Do not remove the contact pads
11
on the back-
side of the measuring tool.
If the measuring tool should fail despite the care
taken in manufacturing and testing procedures,
repair should be carried out by an authorised after-
sales service centre for BTI power tools. Do not
open the measuring tool yourself.
In all correspondence and spare parts orders,
please always include the 7-digit article number
given on the nameplate of the measuring tool.
Store and transport the measuring tool only in the
supplied protective pouch.
In case of repairs, send in the measuring tool
packed in its protective pouch
17
.
Disposal
Measuring tools, accessories and packaging
should be sorted for environmental-friendly recy-
cling.
Do not dispose of measuring tools and batteries/
rechargeable batteries into household waste!
Only for EC countries:
According to the European Guide-
line 2002/96/EC, measuring tools
that are no longer usable, and ac-
cording to the European Guideline
2006/66/EC, defective or used bat-
tery packs/batteries, must be col-
lected separately and disposed of in
an environmentally correct manner.
Subject to change without notice.
OBJ_BUCH-1832-001.book Page 25 Monday, December 10, 2012 12:56 PM