4. DCFC EVDSP-350-5-480-0-1-C-3-0 (C CCS)
DC power Dispenser (Dual Cord):
Auxiliary Input Voltage
120 VAC, single phase, +10%, -10%
Auxiliary Input Current
20 Amps
Frequency
47 – 63 Hz for three phase inputs
Power Quality
IEEE-519 and IEC 6200-3-4
Maximum Output Power CCS
350 KW.
Maximum DC Output Current CCS, non-
continuous
500 Amps.
Maximum DC Output Current CCS,
continuous
Note:
Rating of the H & S liquid cooled cable subsystem
is to be evaluated later for continuous operation
Rating of all other components except H & S liquid
cooled cable are for continuous 500 Amp
operation.
Maximum Output Power CHAdeMO
100 KW.
Maximum DC Output Current CHAdeMO,
non-continuous
250 Amps.
Maximum DC Output Current CHAdeMO,
continuous
200 Amps
Minimum Current (In current mode)
5 Amps
DC power input voltage range
50-920 VDC
DC power input current range
5 Amps – 500 Amps
Outdoor enclosure
NEMA 4, IP 54 equivalent
Chilled 50/50 ethylene glycol
20 C input Temperature, Flow rate = 10 l/min.
Weight
600 lbs.
5. DCFC EVDSP-350-3-480-0-2-C-3-0 (Dual CCS)
DC power Dispenser (Single Cord):
Auxiliary Input Voltage
120 VAC, single phase, +10%, -10%
Auxiliary Input Current
20 Amps
Frequency
47 – 63 Hz for three phase inputs
Power Quality
IEEE-519 and IEC 6200-3-4
Maximum Output Power CCS
200 KW.
Maximum DC Output Current CCS, non-
continuous
500 Amps.
Maximum DC Output Current CCS,
continuous
Note:
Rating of the H & S liquid cooled cable subsystem is
to be evaluated later for continuous operation