Only 2 wires are connected to terminals 2 and 5.
Leave the 2 wires that are not used coiled up
neatly in the back of the socket for future use.
Pull the plastic wire grip tight, trapping the wire.
Finally, fit the front plate onto the backbox with
the screws provided.
7
Remove the lower cover from the Ultimate 106.
There are 6 sets of twin screw connectors.
The telephone extension cable contains 4 strands
of wire, 2 with broad orange or blue stripes, 2 with
narrow orange or blue stripes.
Strip the insulation cable off at the end in order
to expose 5mm of copper wire for the blue or
orange strands.
Power
Day/Night Mode
In Use
Messages
Call Director/Answer Machine
Ultimate 106
EXT 11
EXT 12
EXT 13
EXT 14
EXT 15
EXT 16
Ext 11 Ext 12 Ext 13 Ext 14 Ext 15 Ext 16
Telephone
Line
External Music On Hold Input Normal Program
Doorlock/
Intercom
12v/ 12v/
Com N.O. N.C.
●
2
Connect the extension sockets to
the Ultimate 106
Plastic wire grip
IMPORTANT
If you have connected the 2 blue strands to the
socket, you must also connect the blue strands to
the twin screw connectors in the Ultimate 106.
Equally, if you have connected the 2 orange
strands to the extension socket, you must connect
the 2 orange strands to the twin screw connector.