Troubleshooting
Error codes
© BT
Repair manual
SWE100, 120, 120L, 120S, 140, 140L, 200D
7 – 15
Order no..
Date
Valid from serial no.
T code
258946-120
2012-08-30
6061850-
841×842×843
3.533
Transistor regulator stops all functions.
The charging voltage for the transistor
regulator capacitor indicates abnormal
values.
Check:
•
connections and wiring harness
•
cable 20
•
the transistor regulator.
•
pump contactor
If the error persists, change the
transistor regulator.
3.534
Transistor regulator stops all functions.
The transistor regulator has detected a
problem with the speed sensor.
Excessive frequency fluctuations.
Check:
•
connections and wiring harness
•
the speed sensor and replace if
needed.
3.535
Transistor regulator stops all functions.
Incorrect checksum for the transistor
regulator parameters.
Download the latest software to the
handle and the transistor regulator.
3.536
Transistor regulator stops all functions.
The transistor regulator current supply
unit is outside the valid range.
Internal transistor regulator error.
Replace the transistor regulator.
3.537
Transistor regulator stops all functions.
Multi-direction command issued by
handle.
Internal error in handle.
3.538
The main contactor is open.
Unknown error in the transistor
regulator.
•
Internal transistor regulator error.
Reprogram the transistor regulator.
•
If the error persists, change the
transistor regulator.
Code
Event
Possible cause
Action