12- 6
Service Manual
LWE130
© BT Europe AB
Electrical system – 5000
Accessing main electrical panel
T-code
Valid from serial number
Date
Order number
675
914369-
2005-09-23
226057-040
12.4 Accessing main electrical panel
Access must be gained to the main electrical panel - Fig. 3 B when per-
forming any of the following:
•
Checking the alarm status LED.
•
Connecting the hand terminal to the transistor regulator.
•
Checking / changing any of the fuses.
•
Checking / changing any of the components mounted on the panel.
•
For inspection of the traction motor or hydraulic unit.
NOTE!
Before removing the electrical panel ensure the key switch [S17] is off
and the charger’s mains plug is neither plugged into the start inter-
lock [S170] or any mains outlet socket. For maximum safety it is ad-
visable to also remove the negative connection from battery [G2].
•
Remove the screws securing the main cover (Fig. 3 A) and lift the
cover free of the truck.
•
Remove the two securing screws holding the main electrical panel in
place (Fig. 3 B).
•
Lift the panel vertically approx. 1 cm.
•
The upper edge of the panel can now be lifted away from the truck
and the panel can be “folded out”. The panel can now be positioned
allowing it to “rest” in the folded out position.
•
Ensure no undue strain is put on any cables in the wiring loom.
A
B
Fig. 3 Access to electrical
panel
Fig. 4 “folded out” electrical. panel
https://www.besttruckmanuals.com/