LPG Tank and Related Parts
© BT Industries AB 180424-040
68
LPG Tank and Related
Parts
Outflow Valve
This valve controls the flow of LPG fuel from the LPG tank to the
regulator.
To open the valve.................turn it counterclockwise.
To shut the valve...................turn it clockwise.
Inflow Valve
LPG is filled in the tank through this valve. The tank must be
filled by an LPG filling station attendant. Be sure that this valve is
shut tightly at all times during use.
Pipe Valve
When the fuel hose needs to be disconnected for tank replace-
ment, etc., close this valve to prevent the liquid from running out
of the hose. This valve is normally left open.
To open the valve..................turn it counterclockwise.
To shut the valve....................turn it clockwise.
Relief Valve (Australian market type)
This valve prevents explosion that might be caused when the
LPG pressure rises above a normal level or when the hose
becomes deteriorated.