BT Versatility
Broadband Module/Broadband Module Plus Manual
80
regardless of whether data is present or not until the call is
manually disconnected.
If the Initial Period is set to zero, and the Recurring period is set
to a non-zero value, then the call is only monitored for idle
periods during the Recurring Period.
If the Initial Period is set to a non-zero value, and the Recurring
Period is set to zero, then the call is only monitored for idle
periods during the Initial Period. If the call is still connected after
the Initial Period, it will remain connected until manually
disconnected.
Maximum Calls/day
A call counter sets a threshold on the maximum number of ISDN
calls allowed per day. When this threshold is exceeded, ISDN is
disabled. This is designed to control the number of calls
inadvertently made by applications without the knowledge of the
user. The range is 0 -1000. When this is set to 0 (the default
setting), there is no limit on the number of calls that can be made.
The counter is automatically set to zero at midnight each day.
Auto Recovery On
When enabled, the auto recovery timer becomes active.
Auto Recovery Timer
A timer option is provided to automatically re-enable the ISDN
after the retry threshold is reached. The timer range is 1 - 120
minutes. The default setting is 30 minutes.
•
Enter the new parameters
•
Select "Change" ("Reset" restores the default values)
ADSL T
EST
This performs a series of diagnostic tests on the ADSL connection and displays the test results.
•
Select “Perform ADSL Test”
The tests are performed and the results are displayed.
Result Test Diagnostic
Cause
Passed User
diagnostics
complete
-
ADSL connection OK
Failed
Physical connection
WAN port
connecting:
handshaking
ADSL line
disconnected