Technical data
Model
EcoPAC 04
EcoPAC 06
EcoPAC 08
EcoPAC 10
Heating power
Air 27°C / Water 27°C
3,8 kW
5,8 kW
8,7 kW
11,0 kW
COP
Air 27°C / Water 27°C
4,6
4,6
5,0
5,1
Heating power
Air 15°C / Water 26°C
2,9 kW
4,8 kW
6,5 kW
8,8 kW
COP
Air 15°C / Water 26°C
4,9
5,0
5,1
5,1
Compressor
Toshiba
Toshiba
Toshiba
Toshiba
Intensity (maximum)
3,1 A (6,5 A)
4,7 A (7,0 A)
7,0 A (10,5 A)
8,9 A (13,4 A)
Refrigerant (R410a)
0,50 kg
0,60 kg
1,00 kg
1,30 kg
CO² equivalent
1044,0 kg
1 252,8 kg
2 088,0 kg
2 714,4 kg
Hydraulic connection
1,5" / 50 mm
1,5" / 50 mm
1,5" / 50 mm
1,5" / 50 mm
Power supply
230V / 1~+N / 50 Hz 230V / 1~+N / 50 Hz 230V / 1~+N / 50 Hz 230V / 1~+N / 50 Hz
Minimum water flow
3 m³/h
3 m³/h
4 m³/h
5 m³/h
Noise level (at 10m)
34 dB(a)
34 dB(a)
35 dB(a)
35 dB(a)
Working range
0°C -> 35°C
0°C -> 35°C
0°C -> 35°C
0°C -> 35°C
Dimentions
(L x w x h)
808 x 300 x 546
808 x 300 x 546
942 x 426 x 721
942 x 426 x 721
Contains fluorinated greenhouse gases covered by the Kyoto protocol (50% R32 - CH2F2 / 50% R125 - F3CHF2), in a
hermetically sealed circuit.
At the end of product lifetime, it must imperatively be entrusted to a qualified professional (refrigeration
technician) in order to dismantle it in accordance with the laws in force (recovery of cooling gas, of metallic
materials which can be recycled...).
Содержание EcoPAC 04
Страница 2: ...3...
Страница 15: ...16...
Страница 28: ...29...
Страница 41: ...42...
Страница 54: ...55 EcoPAC 04 EcoPAC 06...
Страница 55: ...56 EcoPAC 08...
Страница 56: ...57 EcoPAC 10...
Страница 57: ...58 Pompa di calore di piscina...
Страница 70: ...71 EcoPAC 04 EcoPAC 06...
Страница 71: ...72 EcoPAC 08...
Страница 72: ...73 EcoPAC 10...