About Safety
2
iPQ-Spectral – Spectral measuring head (C11 SensorUnit)
11/38
CAUTION
Danger of crushing caused by pneumatically driven backing wheel
The backing wheel of the motorized backing unit is moved toward
the printed web by means of a pneumatic system. Excessive pres-
sure leads to a risk of injury between the backing wheel and the
printed web.
►
Ensure that the pressure reducer connected to the backing unit
is set to 1.8 bar.
Normal operation
Observe the following safety instructions during
normal operation
of the system.
CAUTION
Blinding due to looking into a bright light source!
Directly looking into bright light sources can lead to impaired vision
and subsequent accidents.
►
Never look directly at the light source while it is switched on!
►
Take suitable measures (shielding, blocking) to ensure that dir-
ectly looking at the light source is impossible.
CAUTION
Danger of crushing caused by motorized traverse bar!
There is a danger of crushing when body parts enter the space
between the camera unit/spectral measuring head and traverse
bar!
►
Prior to starting assembly, maintenance and cleaning work, isol-
ate the system and secure it against being switched on again.
►
Ensure that no body parts are within the hazard zone of the tra-
verse bar.
Maintenance, cleaning,
troubleshooting
Observe the following safety instructions during
maintenance,
cleaning and troubleshooting
on the system.
WARNING
Risk of electrocution and damage to the spectral measuring head
caused by unauthorized opening!
Severe injuries caused by live components with up to 1000 V!
Damage to highly sensitive optical / electronic components due to
touching, soiling or vibration.
►
Only allow BST service personnel or other authorized personnel
to open, perform maintenance on or repair the spectral meas-
uring head.
►
Exercise the greatest possible caution during any work on or
with the spectral measuring head.
►
Note the information on safe handling of the spectral measur-
ing head.