DCP-555 Help File
24
In Meter
This meter displays incoming signal level in dBu.
Threshold
Use this slider or field to adjust the level at which compression will occur.
Attack
Use this slider or field to adjust how quickly the Compressor will clamp down on the
signal. Lower values will clamp down on the signal quickly, whereas higher values will
let some of the signal pass before clamping down on the signal.
Release
Use this slider or field to adjust how quickly the Compressor will release the
compressed signal once it falls back below threshold.
Gain Reduction Meter
This meter displays the amount of gain reduction being applied to the signal.
Ratio
Use this slider or field to adjust how much compression will be applied once the
threshold has been exceeded. Use higher ratios to apply more compression and lower
ratios for subtle compression.
Gain
Use this slider or field to adjust the output gain to makeup for gain lost due to
compression.
Содержание DCP-555
Страница 1: ...DCP 555 Help File...
Страница 10: ......
Страница 24: ...DCP 555 Help File 14 Press this button to open the Dialer for the selected VoIP input line...
Страница 26: ...16 AES67 Input Type This feature to be implemented in a future firmware release...
Страница 43: ...33 AES67 Output Type This feature to be implemented in a future firmware release...
Страница 58: ...DCP 555 Help File 48 This field displays the MAC address of the DCP 555 s VoIP port...
Страница 59: ...49 VoIP Line 1 4 Settings...
Страница 69: ...59 GPI Ports...
Страница 78: ......
Страница 83: ...73...