BSC SRV300 Скачать руководство пользователя страница 3

 

 

1

 

Introduction 

Thank you very much for using our products. 

You are kindly requested, upon delivery of the product, to check that the delivered product is 
exactly what you have ordered and it has no damage caused by transport or the like. lf there is 
any damage, defect, or missing parts, please do not hesitate to contact with us. 

Important safety information 

This instruction provides installation, operation, and maintenance instructions for the 

rotary vane vacuum pump SRV300. In order for you to use this product safely and effectively, 
please read it carefully and strictly follow the instructions in the manual. SRV300 is 
hereinafter referred to as pump. 

This product must be installed, operated, and maintained by trained personnel. Install 

and use in accordance with national and local safety regulations or ordinances. 

 

 

Warning 

Follow the safety instructions below and take appropriate 

precautions. Otherwise, it may cause personal injury and 
equipment    damage.

 

 

 

All power sources connected to the pump must be disconnected before any 
maintenance or service work is performed on the pump. Take appropriate 
measures to ensure that the pump cannot be started and the power supply 
cannot be accidentally switched on. If the pump has  pumped  hazardous 
gases, the  nature of the hazardous substance must be determined and 
appropriate safety precautions must be taken. 

 

When the pump is running, the exhaust airflow must not be blocked. 
Because this will increase the internal pressure of the pump, which will 
cause the pump casing and oil level window to crack, leak oil or overload the 
motor. 

 

Please do not run the pump without refueling or insufficient oil quantity.     
This will easily cause pump wear and affect the performance and service life 
of the pump. 

 

Always check the oil level and oil quality when the pump is running. 

 

Содержание SRV300

Страница 1: ...Instruction Manual VERSION 1 0 Single stage oil sealed rotary vane vacuum pump SRV300...

Страница 2: ...ping of Condensable Gases and Vapors 9 6 7 3 Cyclic process 10 6 8 Stop 11 6 9 Ultimate pressure 11 7 Maintenance 12 7 1 Maintenance schedule 12 7 2 Checking the oil 13 7 2 1 Oil level 13 7 2 2 Oil co...

Страница 3: ...or ordinances Warning Follow the safety instructions below and take appropriate precautions Otherwise it may cause personal injury and equipment damage All power sources connected to the pump must be...

Страница 4: ...ith explosion danger to avoid injury or fire Do not place flammable materials around the motor and the pump body to prevent fire Do not place any obstructions that obstruct ventilation around the moto...

Страница 5: ...n fine filtering occurs in the exhaust filter elements The proportion of oil in the exhaust gas is thus reduced below the visibility threshold over 99 entrapment rate Oil trapped in the exhaust filter...

Страница 6: ...pump Pumps are not designed for pumping of aggressive corrosive flammable or explosive gases These pumps are not designed for working in flammable or explosive environment The pump is not suitable fo...

Страница 7: ...5 Installation diagram 7...

Страница 8: ...e line is too narrow it reduces the pumping speed We recommend applying either LOCTITE or TEFLON tape to the screwed unions so that they are vacuum tight especially if gases are dangerous Pump should...

Страница 9: ...overpressure may occur in the pump Install the exhaust line with a downward slope to prevent condensate from flowing back into the pump If this is not possible we strongly recommend to install a conde...

Страница 10: ...ician in accordance with the applicable safety regulations Wire the motor for the correct supply voltage via connections in the junction box See the wiring diagram on the motor name plate For proper c...

Страница 11: ...the intake to check vacuum Exposure of a part of the body to the vacuum result in a rush of blood in the exposed part 6 7 Operation The pump gases and vapors provided that the gas ballast valve is ins...

Страница 12: ...le vapors until it has warmed to operating temperature pumping process gas with a cold pump results in vapors condensing in the oil For processes with a high proportion of condensable vapors slowly op...

Страница 13: ...ust be cooled down to the ambient temperature and must only be switched on again manually after having eliminated the cause In order to prevent the pump from running up unexpectedly after a main power...

Страница 14: ...nt conditions and or aggressive media may necessitate more frequent maintenance Maintenance job Frequency Section Check the oil level daily 7 2 1 Check the oil condition Depends on process 7 2 2 1st o...

Страница 15: ...operating temperature Depending on the process involved dangerous substances may escape from the pump and oil Take the appropriate precautions 7 3 Oil Change Always change the oil when the pump is sw...

Страница 16: ...that the filter element spring is behind the W shaped filter element bracket 6 Slowly insert the two positioning pins on the exhaust port cover into the corresponding holes in the W shaped filter ele...

Страница 17: ...mm away from the bottom side of the intake port Depending on the process involved dangerous substances may escape from the pump and oil Take the appropriate precautions 7 7 Radiator cleaning Please ke...

Страница 18: ...he pump The gas ballast must be closed and if the pump is to be shelved for a longer period of time it should be sealed in a plastic bag together with a desiccant If the pump has been shelved for more...

Страница 19: ...red without our company s consent 5 Failures and defects caused by abnormal working environment strong electromagnetic radioactive environment high temperature high humidity flammable gas environment...

Страница 20: ...ernal leak 1 Piping fittings loose Repair the pump Retighten Anti suck back valve is malfunctioning Repair the valve Exhaust valve is malfunctioning Repair the valve Float valve does not close Repair...

Страница 21: ...n intake line or in vacuum vessel Oil comes from the vacuum system Check the vacuum system Anti suck back valve is obstructed Clean or repair the valve Sealing surfaces or anti suck back valve are dam...

Страница 22: ...l elapsed time about 24hr continuous operation Intermittent operation Whether exposure to pollutants Yes No Name and Chemical formula pollutants Nature and character of pollutants Cleaning solvents an...

Страница 23: ...uipment Co Ltd Add No 55 Juchao Road Jiangkou subdistrict Fenghua District Ningbo City Zhejiang Province China Post code 315500 Tel 0574 88569588 59516555 Fax 0574 88569596 Email bsvac cnbaosi com Htt...