* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard:
80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard:
70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temp Heating Standard:
70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.
† Outdoor section/indoor section combination tested in accordance with DOE test procedure for heat pumps.
‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type.
** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.
Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR.
†† Indoor Airflow
‡‡ Must replace Factory-supplied R-22 TXV with Puron TXV.
COP
— Coefficient of Performance
TC
— Total Capacity (Btuh)
EER
— Energy Efficiency Ratio
TDR
— Time-Delay Relay
HSPF
— Heating Seasonal Performance Factor
TXV
— Thermostatic Expansion Valve
SEER
— Seasonal Energy Efficiency Ratio
048-D,
E, F
CK5A/CK5BT060
45,000
TDR
—
—
12.50
—
10.90
47,500
3.44
28,200
2.36
8.1
CK5A/CK5BX060
45,000
TDR
—
—
12.70
—
11.10
47,500
3.48
28,200
2.38
8.1
CK5PA060
45,000 TDR&TXV
12.50
—
—
—
10.90
47,500
3.44
28,200
2.36
8.1
CK5PT060
45,000 TDR&TXV
12.50
—
—
—
10.90
47,500
3.44
28,200
2.36
8.1
CK5PX060
45,000 TDR&TXV
12.70
—
—
—
11.10
47,500
3.48
28,200
2.38
8.1
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
43,000
TDR
—
13.00
—
—
11.05
46,500
3.18
27,600
2.28
7.5
CC5A/CD5AW048
43,000
TDR
—
13.00
—
—
11.00
47,000
3.22
27,600
2.28
7.5
CD5PX060
44,500 TDR&TXV
13.50
—
—
—
11.40
48,000
3.54
28,400
2.40
8.0
CK3BA060
45,000
TDR
—
—
13.00
—
11.30
47,000
3.52
27,800
2.40
8.2
CK5A/CK5BA060
45,000
TDR
—
—
13.00
—
11.25
47,000
3.50
27,800
2.40
8.2
CK5A/CK5BT060
45,000
TDR
—
—
13.00
—
11.25
47,000
3.50
27,800
2.40
8.2
CK5A/CK5BX060
45,500
TDR
—
—
13.50
—
11.45
47,500
3.54
27,800
2.44
8.3
CK5PA060
45,000 TDR&TXV
13.00
—
—
—
11.25
47,000
3.50
27,800
2.40
8.2
CK5PT060
45,000 TDR&TXV
13.00
—
—
—
11.25
47,000
3.50
27,800
2.40
8.2
CK5PX060
45,500 TDR&TXV
13.50
—
—
—
11.45
47,500
3.54
27,800
2.44
8.3
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
43,000
TDR
—
13.00
—
—
11.05
46,500
3.18
27,400
2.28
7.5
CC5A/CD5AW048
43,000
TDR
—
13.00
—
—
11.05
47,000
3.22
27,400
2.30
7.5
CK5A/CK5BA060
45,000
TDR
—
—
13.00
—
11.30
47,000
3.52
27,800
2.40
8.2
CK5A/CK5BT060
45,000
TDR
—
—
13.00
—
11.30
47,000
3.52
27,800
2.40
8.2
CK5A/CK5BX060
45,500
TDR
—
—
13.50
—
11.45
47,500
3.54
27,800
2.44
8.3
CK5PA060
45,000 TDR&TXV
13.00
—
—
—
11.30
47,000
3.52
27,800
2.40
8.2
CK5PT060
45,000 TDR&TXV
13.00
—
—
—
11.30
47,000
3.52
27,800
2.40
8.2
CK5PX060
45,500 TDR&TXV
13.50
—
—
—
11.45
47,500
3.54
27,800
2.44
8.3
060-D, E
*FV4BNB006
58,000 TDR&TXV
13.00
—
—
—
10.75
60,000
3.56
37,000
2.54
8.1
CC5A/CD5AW060
56,000
NONE
—
—
12.50
—
10.45
58,500
3.26
36,800
2.42
7.6
CD5PX060
56,500
TXV
—
—
—
12.00
10.25
60,000
3.46
37,600
2.48
8.0
CK5A/CK5BX060
56,500
NONE
—
—
12.50
—
10.55
59,000
3.44
37,000
2.50
7.8
CK5PX060
56,500
TXV
—
—
—
12.50
10.55
59,000
3.44
37,000
2.50
7.8
FB4BNB070
57,000
TDR
—
12.20
—
—
10.20
60,000
3.44
37,800
2.46
7.8
FC4CNB070
57,000 TDR&TXV
—
12.20
—
—
10.20
60,000
3.44
37,800
2.46
7.8
FE4ANB006
58,000 TDR&TXV
13.00
—
—
—
10.75
60,000
3.56
37,000
2.54
8.1
FK4DNB006
58,000 TDR&TXV
—
13.00
—
—
10.75
59,500
3.56
37,000
2.54
8.0
FX4BNB060
57,000 TDR&TXV
12.10
—
—
—
10.20
60,000
3.44
37,800
2.46
7.8
COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE
CD5PX060
56,500 TDR&TXV
12.50
—
—
—
10.50
59,000
3.52
37,200
2.52
8.0
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CC5A/CD5AW060
56,000
TDR
—
12.50
—
—
10.55
58,500
3.28
36,600
2.44
7.6
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CD5PX060
55,500 TDR&TXV
12.00
—
—
—
9.90
60,000
3.36
37,800
2.42
7.5
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CD5PX060
56,000 TDR&TXV
12.00
—
—
—
10.05
60,000
3.40
37,600
2.44
7.5
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CD5PX060
55,000 TDR&TXV
12.00
—
—
—
10.15
61,000
3.40
37,400
2.44
7.5
UNIT
SIZE-
SERIES
INDOOR
UNIT
CFM††
ARI STANDARD RATINGS*
Cooling
Heating
TC
Seasonal Efficiency SEER
EER
High-Temp
Low-Temp
HSPF
Factory-
Supplied
Enhance-
ment
Standard
Rating
Field-Supplied
Accessory‡
Puron
TXV
Puron
TXV
& TDR**
TC
COP
TC
COP
COMBINATION RATINGS continued