15
RVS/Heat Stage 2
O/B W2
Heat Stage 1
W/W1
Compressor Low
Y1
Compressor High
Y/Y2
Fan
G
24VAC Hot Heating
Rh
24VAC Hot Cooling
Rc
Dry Contact 1
D1
Dry Contact 2
D2
24VAC Common
C
Humidify
HUM
Outdoor Air Temp
OAT
Remote Room Sensor
RRS
OAT/RRS Com
OAT/RRS
Outdoor Sensor *
Humidifier Solenoid
Valve *
Remote Room
Sensor *
O
Y1
W1
G
W2
C
Y2
R
W1
Y1
O
Y/Y2
R
C
DH
REMOVE J2
JUMPER FOR
HEAT STAGING
REMOVE J1 FOR
DEHUMIDIFY
MODES
2 STAGE
HEAT PUMP
THERMIDISTAT
FAN
COIL
A08055
Fig. 10 -- Edge Thermidistat Models T6--PRH--01 or T6--NRH--01)
Wiring with Two--Stage Heat Pump (non--communicating)
O
O/B W2
W2
W/W1
W/W1
W2
*
Heat/Cool Stage 1
Y1 / W2
Y1
Heat/Cool Stage 2
Y/Y2
Y/Y2
Y/Y2
Fan
G
G
24VAC Hot Heating
Rh
R
R
24VAC Hot Cooling
Rc
Dry Contact 1
D1
Dry Contact 2
D2
DHUM
24VAC Common
C
COM
C
Humidify
HUM
Outdoor Air Temp
OAT
Remote Room Sensor
RRS
OAT/RRS Com
SRTN
Outdoor Sensor *
Humidifier Solenoid
Valve *
Remote Room
Sensor *
Variable Speed
Furnace
Thermidistat
2-Stage
Heat Pump
* Indicates connection may not be required / available.
Heat Stage 3 (furnace)
RVS Cooling
A09337
Fig. 11 -- Thermidistat Model T6--PRH--01 or T6--NRH--01 with
Variable Speed Furnace and 2--Stage Heat Pump
(non--communicating)
D
C
B
A
User Interface
D
C
B
A
D
C
B
A
Communicating HP
OA
T
R
Y
O
W
C
HUM
C
Humidifier
24v
ac
Furnace or Fan Coil
A08091
Fig. 12 -- Evolution Furnace or Fan Coil Wiring with 286A OR 288A Communicating Two--Stage HP
286A
/288A