25
Table 7—
Heating Inputs
HEATING INPUT (BTU/HR)*
NUMBER OF
GAS SUPPLY PRESSURE (IN. WG)
MANIFOLD PRESSURE (IN. WG)
HEATING INPUT (BTU/HR)*
NUMBER OF
ORIFICES
Natural
Natural
High Stage
Low Stage
ORIFICES
Min
Max
High Stage
Low Stage
40,000
26,000
2
4.0
13.0
3.2
∼
3.8
1.4 ∼
2.0
60,000
39,000
3
4.0
13.0
3.2
∼
3.8
1.4 ∼
2.0
90,000
58,500
3
4.0
13.0
3.2
∼
3.8
1.4 ∼
2.0
115,000
75,000
3
4.0
13.0
3.2
∼
3.8
1.4 ∼
2.0
130,000
84,500
3
4.0
13.0
3.2
∼
3.8
1.4 ∼
2.0
*Cubit ft of natural gas per hour for gas pressures of .5 psig (14 in. wc) or less and a pressure drop of .5 in. wc (based on a .60 specific gravity gas). Ref: Table 12.2 ANSI
Z223--2002/NFPA 54--2002.
IMPORTANT
: When evaluating the refrigerant charge, an
indicated adjustment to the specified factory charge must always be
very minimal. If a substantial adjustment is indicated, an abnormal
condition exists somewhere in the cooling system, such as
insufficient airflow across either coil or both coils.
REFRIGERANT CHARGE
The amount of refrigerant charge is listed on the unit rating plate
and/or the physical data table. Refer to the Refrigeration Service
Techniques Manual, Refrigerants Section.
NO CHARGE
Check for leak. Use standard evacuating techniques. After
evacuating system, weigh in the specified amount of refrigerant
(refer to system rating plate).
LOW CHARGE COOLING
Use Cooling Charging Chart (Fig. 22). Vary refrigerant until the
conditions of the chart are met. Note that charging charts are
different from type normally used. Charts are based on charging the
units to correct subcooling for the various operating conditions.
Accurate pressure gauge and temperature sensing devices are
required. Connect the pressure gauge to the service port on the
suction line. Mount the temperature sensing device on the suction
line and insulate it so that the outdoor ambient does not affect the
reading. Indoor air CFM must be within the normal operating range
of the unit.
TO USE COOLING CHARGING CHARTS
Take the liquid line temperature and read the manifold pressure
gauges.
Refer to the chart to determine what the liquid line temperature
should be.
NOTE
: If the problem causing the inaccurate readings is a
refrigerant leak, refer to Check for Refrigerant Leaks section.
NON--COMMUNICATING
EMERGENCY
COOLING
/
HEATING MODE: 4--WIRE THERMOSTAT
This mode of operation is provided only in the case where the UI has
failed or is otherwise unavailable. If communications cannot be
established with the UI, the Evolution furnace board will enable the
standard thermostat input terminals to allow simple thermostatic
control of the 577D unit.
For control with a standard thermostat, disconnect the ABCD
connectors from both control boards and using No. 18 AWG
color--coded, insulated type 90
°
C minimum or equivalent wire,
make the connections between the standard thermostat, the furnace
board, and the HP/AC board per Fig. 21. Recommend the use of
interconnecting wire with 105C, 600V, 2/64” insulation.
The Evolution control will respond to cooling and heating demands
with the maximum safe airflow based on gas furnace output and unit
cooling capacity.
Table 8—
ECM Wet Coil Pressure Drop (in. wg)
UNIT
STANDARD CFM (SCFM)
UNIT
SIZE
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
024
0.005
0.007
0.010
0.012
0.015
–
–
–
–
–
–
–
–
–
–
–
030
–
0.007
0.010
0.012
0.015
0.018
0.021
0.024
–
–
–
–
–
–
–
–
036
–
–
–
0.019
0.023
0.027
0.032
0.037
0.042
0.047
–
–
–
–
–
–
042
–
–
–
–
0.014
0.017
0.020
0.024
0.027
0.031
0.035
0.039
0.043
–
–
–
048
–
–
–
–
–
–
0.027
0.032
0.036
0.041
0.046
0.052
0.057
0.063
0.068
–
060
–
–
–
–
–
–
–
–
–
0.029
0.032
0.036
0.040
0.045
0.049
0.053
Table 9—
Filter Pressure Drop Table (in. wg)
FILTER SIZE
CFM
FILTER SIZE
500
600
700
800
900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300
20X20X1
0.05 0.07 0.08
0.1
0.12 0.13 0.14 0.15
—
—
—
—
—
—
—
—
—
—
—
24X30X1
—
—
—
—
0.05
0.6
0.07 0.07 0.08 0.09
0.1
—
—
—
—
—
—
—
—
24X36X1
—
—
—
—
—
—
—
0.06 0.07 0.07 0.08 0.09 0.09 0.10 0.11 0.12 0.13 0.14 0.14