CONDENSER ONLY RATINGS* CONTINUED
SST
° F (° C)
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
55 (12.78)
65 (18.33)
75 (23.89)
85 (29.44)
95 (35.0)
105 (40.56)
115 (46.11)
125 (51.67)
186BNA036****A
30
(---1.11)
TCG
30.50
29.20
27.80
26.30
24.70
23.00
21.20
19.20
SDT
69.50
78.70
87.90
97.20
106.60
115.90
125.20
134.50
KW
1.41
1.62
1.85
2.10
2.37
2.69
3.07
3.51
35
(1.67)
TCG
33.70
32.20
30.70
29.10
27.40
25.50
23.60
21.50
SDT
70.70
79.90
89.10
98.30
107.50
116.80
126.10
135.40
KW
1.41
1.63
1.86
2.11
2.38
2.70
3.07
3.51
40
(4.44)
TCG
37.10
35.50
33.80
32.10
30.20
28.20
26.10
23.90
SDT
72.10
81.20
90.30
99.50
108.60
117.80
127.10
136.30
KW
1.42
1.64
1.87
2.12
2.40
2.71
3.08
3.52
45
(7.22)
TCG
40.80
39.00
37.20
35.30
33.20
31.10
28.80
26.40
SDT
73.70
82.60
91.60
100.70
109.80
118.90
128.10
137.20
KW
1.43
1.65
1.88
2.13
2.41
2.73
3.10
3.53
50
(10.0)
TCG
44.80
42.80
40.80
38.70
36.50
34.10
31.70
29.00
SDT
75.30
84.10
93.10
102.00
111.00
120.10
129.10
138.10
KW
1.45
1.67
1.90
2.15
2.43
2.75
3.12
3.54
55
(12.78)
TCG
48.90
46.80
44.60
42.30
39.90
37.40
34.70
31.80
SDT
77.00
85.70
94.60
103.40
112.30
121.30
130.20
139.10
KW
1.47
1.70
1.93
2.18
2.46
2.77
3.14
3.56
186BNA042000BAAA
30
(---1.11)
TCG
32.80
32.10
31.20
30.10
28.70
27.20
25.40
23.50
SDT
69.80
79.20
88.70
98.10
107.40
116.70
125.90
135.10
KW
1.61
1.84
2.12
2.45
2.84
3.29
3.81
4.40
35
(1.67)
TCG
36.20
35.50
34.50
33.20
31.80
30.10
28.20
26.10
SDT
71.20
80.60
89.90
99.20
108.40
117.70
126.80
136.00
KW
1.62
1.86
2.14
2.47
2.86
3.31
3.83
4.42
40
(4.44)
TCG
39.90
39.00
37.90
36.60
35.00
33.20
31.10
28.90
SDT
72.70
81.90
91.20
100.40
109.60
118.70
127.80
136.90
KW
1.63
1.87
2.15
2.49
2.88
3.33
3.85
4.45
45
(7.22)
TCG
43.90
42.90
41.60
40.10
38.40
36.40
34.20
31.80
SDT
74.20
83.30
92.50
101.60
110.80
119.90
128.90
137.90
KW
1.64
1.88
2.17
2.51
2.91
3.36
3.88
4.48
50
(10.0)
TCG
48.10
46.90
45.50
43.90
42.00
39.80
37.40
34.80
SDT
75.80
84.80
93.90
103.00
112.00
121.00
130.00
138.90
KW
1.65
1.90
2.19
2.54
2.94
3.39
3.92
4.51
55
(12.78)
TCG
52.50
51.20
49.60
47.80
45.70
43.40
40.70
37.90
SDT
77.40
86.40
95.40
104.40
113.40
122.30
131.20
140.00
KW
1.67
1.92
2.22
2.57
2.97
3.43
3.96
4.55
186BNA048000BAAA
30
(---1.11)
TCG
36.00
34.90
33.70
32.40
31.00
29.30
27.40
25.30
SDT
67.60
77.00
86.40
95.80
105.10
114.50
123.80
133.10
KW
2.10
2.37
2.62
2.87
3.13
3.41
3.72
4.08
35
(1.67)
TCG
39.80
38.60
37.30
35.80
34.20
32.40
30.40
28.10
SDT
68.90
78.20
87.50
96.80
106.10
115.30
124.60
133.80
KW
2.03
2.33
2.61
2.88
3.14
3.43
3.74
4.09
40
(4.44)
TCG
44.00
42.60
41.10
39.50
37.70
35.70
33.50
31.00
SDT
70.30
79.40
88.60
97.80
107.00
116.30
125.40
134.60
KW
1.92
2.26
2.57
2.86
3.14
3.44
3.76
4.11
45
(7.22)
TCG
48.60
47.00
45.30
43.50
41.50
39.30
36.90
34.20
SDT
71.70
80.70
89.80
99.00
108.10
117.30
126.40
135.40
KW
1.76
2.15
2.49
2.81
3.13
3.44
3.77
4.13
50
(10.0)
TCG
53.50
51.70
49.80
47.80
45.50
43.10
40.40
37.40
SDT
73.20
82.10
91.20
100.20
109.30
118.30
127.30
136.30
KW
1.57
2.00
2.38
2.74
3.09
3.42
3.77
4.14
55
(12.78)
TCG
59.00
56.90
54.70
52.40
49.90
47.20
44.20
40.90
SDT
74.80
83.60
92.60
101.50
110.50
119.40
128.40
137.30
KW
1.32
1.81
2.24
2.64
3.02
3.39
3.76
4.14
See notes on page 18
186B