background image

6

Sample Furnace Circuit Board

Power Cord

to EAC Terminals

Alternate Power Cord 

Pass-Thru Hole

Use cable connector to secure

power cord to cabinet

Power Supply Connector

Power Supply

Use wire ties to secure power cord

to power supply enclosure

LHT
OFF
DLY

ON

OFF

W2

BLW

EAC-1 TERMINAL

Y1

DHUM

G

COM

24V

WW1

Y/Y2

R

TEST/TWIN

HUM

1  2  3

PL
T

A

CRDJ

0.5-AMP024 VAC

FUSE 3-AMP

SEC-1

SEC-2

PL1

NEUTRAL-L2

1

EAC-2

BHT/CLR

BHI/LOR

PL3       1

BLWR

COOL

SPARE-1

SPARE-2

1-AMP@115 VAC

EAC-1

PR-1

IDR

HSIR

IDM

IHI/LOR

PL2

1

HSI     HI    LO

STATU

S

C

OD

EL

E

D

EAC-2 TERMINAL

HI HEA

T

LO HEA

T

L1

Use terminals to connect the

power cord wires to the furnace

EAC-1 & 2, & ground terminals

Power Supply Connector

Power Cord

A06030

Fig. 7 -- Perfect Air

t

Purifier Electrical Connections

START--UP AND OPERATION

Step 1

Checking Air Purifier Operation

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury or death.
Before installing or servicing system, always turn off

main power to system. There may be more than one (1)

disconnect switch.

!

WARNING

a. Attach the Perfect Air

t

Purifier door to the cabinet. A

magnet in the door (see Fig. 9) is used to activate a safe-

ty switch in the power supply when the door is installed.

The power supply will not energize the air purifier un-

less the safety switch is activated.

b. Turn the HVAC system power on and adjust the

thermostat or Evolution

t

System Control to activate

the system fan.

c. Turn the Perfect Air

t

Purifier power switch to on

position.

d. The power indicator light above the Air Purifier power

switch should illuminiate (see Fig. 8).

e. Check to ensure the light goes off when the Perfect

Air

t

Purifier power switch is set to off, when the

blower goes off, or when the HVAC system power is

turned off.

Step 2

Evolution

t

Control

a. When the Perfect Air

t

Purifier is used with an

Evolution

t

Control, the Evolution

t

Control can be

configured to remind the homeowner when it is time to

change the Perfect Air

t

Purifier cartridge. This

maintenance reminder can be based on either the

TrueSense

t

dirty filter algorithm or time. The installer

should use their discretion to select the most appropriate

option based on the initial system static pressure.

Step 3

Maximizing Performance

a. Maximum air purification performance is obtained

when the furnace blower is set for continuous operation
on the thermostat or Evolution

t

Control.

Power Indicator

A06065

Fig. 8 -- Power Indicator

MAINTENANCE

The Perfect Air

t

Purifier is designed to require no cleaning.

Maintenance is limited to the replacement of the air purification

cartridge. Frequency of air purifier cartridge replacement may

vary depending on ductwork design and local environmental

conditions.
To replace the air purifier cartridge, complete the following

steps:

GAP

A

Содержание AIRT PURIFIER

Страница 1: ...ptured particles are killed by electrical current flow and ion bombardment A06054 Fig 1 GAPA Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information or as...

Страница 2: ... If the return air duct or furnace openings do not fit the Perfect Air t Purifier cabinet openings gradual transitions are recommended to reduce air turbulence and maximize efficiency No more than 20 degrees about 4 in per running ft of expansion should be used on each side of the transition fitting Turning Vanes If the Perfect Airt Purifier is installed adjacent to a 90 degree duct elbow turning ...

Страница 3: ...of the Perfect Airt Purifier should be readily accessible Enough room should be provided for periodic replacement of the air purifier cartridges ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should install the Perfect Airt Purifier A thorough check of the unit installation should be complete...

Страница 4: ...abinet between the furnace and return air duct see Fig 4 A transition duct may be required e Furnace adapters have been included for installer convenience They are designed for top or bottom mount installations see Fig 5 f Return air duct adapters have been included for installer convenience They should be used to connect the upstream side of the air purifier cabinet to the return air duct see Fig...

Страница 5: ...ply connector see Fig 7 d Route the power cord through nearest cabinet hole and protect with enclosed cable connector Zip ties have been enclosed to secure the power cord to the side of the power supply e Attach the quick connect terminals to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring to furnace chassis ground NOTE The Perfect Airt Purifier is to be powered by 115v 60 Hz ...

Страница 6: ...s the safety switch is activated b Turn the HVAC system power on and adjust the thermostat or Evolutiont System Control to activate the system fan c Turn the Perfect Airt Purifier power switch to on position d The power indicator light above the Air Purifier power switch should illuminiate see Fig 8 e Check to ensure the light goes off when the Perfect Airt Purifier power switch is set to off when...

Страница 7: ...e electrical components Disconnect power between checks and then proceed carefully WARNING The Perfect Airt Purifier is equipped with a power indicator light located on the door see Fig 8 This power indicator light will illuminate when the Perfect Airt Purifier door is installed the power switch is in the on position AND the furnace blower is running If the power indicator light is not illuminated...

Страница 8: ... EAC terminals 115v 60 Hz from furnace EAC terminals Maximum Airflow CFM 1600 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPBBCAR1625 GAPBBCAR2025 Dimensions GAPAAXBB1625 GAPAAXBB2025 A 18 3 8 21 7 8 B 15 1 8 18 5 8 C 11 1 8 11 1 8 D 17 1 2 21 E 22 1 8 22 1 8 F 25 1 4 25 1 4 7 16 Typical Top Bottom 1 3 16 1 3 16 1 3 16 1 15 16 A C E F B D A06069 Fig 10 Dimens...

Страница 9: ...to the distributor through a registered servicing dealer for credit 4 All work shall be performed during normal working hours LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN AND APPLIES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW...

Страница 10: ...or change at any time specifications or designs without notice and without incurring obligations EBryant Heating Cooling Systems 7310 W Morris St Indianapolis IN 46231 Printed in China Edition Date 3 06 Replaces II GAPA 0 1 Catalog No II GAPA 0 2 GAPA ...

Отзывы: