6
Sample Furnace Circuit Board
Power Cord
to EAC Terminals
Alternate Power Cord
Pass-Thru Hole
Use cable connector to secure
power cord to cabinet
Power Supply Connector
Power Supply
Use wire ties to secure power cord
to power supply enclosure
LHT
OFF
DLY
ON
OFF
W2
BLW
EAC-1 TERMINAL
Y1
DHUM
G
COM
24V
WW1
Y/Y2
R
TEST/TWIN
HUM
1 2 3
PL
T
A
CRDJ
0.5-AMP024 VAC
FUSE 3-AMP
SEC-1
SEC-2
PL1
NEUTRAL-L2
1
EAC-2
BHT/CLR
BHI/LOR
PL3 1
BLWR
COOL
SPARE-1
SPARE-2
1-AMP@115 VAC
EAC-1
PR-1
IDR
HSIR
IDM
IHI/LOR
PL2
1
HSI HI LO
STATU
S
C
OD
EL
E
D
EAC-2 TERMINAL
HI HEA
T
LO HEA
T
L1
Use terminals to connect the
power cord wires to the furnace
EAC-1 & 2, & ground terminals
Power Supply Connector
Power Cord
A06030
Fig. 7 -- Perfect Air
t
Purifier Electrical Connections
START--UP AND OPERATION
Step 1
—
Checking Air Purifier Operation
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing or servicing system, always turn off
main power to system. There may be more than one (1)
disconnect switch.
!
WARNING
a. Attach the Perfect Air
t
Purifier door to the cabinet. A
magnet in the door (see Fig. 9) is used to activate a safe-
ty switch in the power supply when the door is installed.
The power supply will not energize the air purifier un-
less the safety switch is activated.
b. Turn the HVAC system power on and adjust the
thermostat or Evolution
t
System Control to activate
the system fan.
c. Turn the Perfect Air
t
Purifier power switch to on
position.
d. The power indicator light above the Air Purifier power
switch should illuminiate (see Fig. 8).
e. Check to ensure the light goes off when the Perfect
Air
t
Purifier power switch is set to off, when the
blower goes off, or when the HVAC system power is
turned off.
Step 2
—
Evolution
t
Control
a. When the Perfect Air
t
Purifier is used with an
Evolution
t
Control, the Evolution
t
Control can be
configured to remind the homeowner when it is time to
change the Perfect Air
t
Purifier cartridge. This
maintenance reminder can be based on either the
TrueSense
t
dirty filter algorithm or time. The installer
should use their discretion to select the most appropriate
option based on the initial system static pressure.
Step 3
—
Maximizing Performance
a. Maximum air purification performance is obtained
when the furnace blower is set for continuous operation
on the thermostat or Evolution
t
Control.
Power Indicator
A06065
Fig. 8 -- Power Indicator
MAINTENANCE
The Perfect Air
t
Purifier is designed to require no cleaning.
Maintenance is limited to the replacement of the air purification
cartridge. Frequency of air purifier cartridge replacement may
vary depending on ductwork design and local environmental
conditions.
To replace the air purifier cartridge, complete the following
steps:
GAP
A