APPLICATION CONSIDERATIONS

The Perfect Air

t

Purifier is designed for use in the return air

duct of a forced air heating, cooling, and ventilation system.

Models GAPAAXBB1625 and GAPAAXBB2025 are

specifically designed for use in systems with a forced air gas

furnace.

Air Conditioning

The Perfect Air

t

Purifier should be installed in a system so

that all the return air is circulated through the air purifier. It

should be located upstream of both the furnace and the air

conditioning evaporator coil. This will help keep the furnace

and evaporator coil clean and prevent condensation from

forming within the Perfect Air

t

Purifier.

Humidifiers

An evaporative humidifier can be mounted upstream of the

Perfect Air

t

Purifier. It is best to install atomizing humidifiers

downstream of the air purifier because hard water salt deposits

and water droplets may damage air purifier. If an atomizing

humidifier must be mounted upstream of the Perfect Air

t

Purifier, it should be mounted as far upstream as possible (at

least 6 ft recommended), and a standard disposable furnace

filter should be mounted between the humidifier and the air

purifier to trap hard water salt deposits and water droplets.

Transitions

If the return air duct or furnace openings do not fit the Perfect

Air

t

Purifier cabinet openings, gradual transitions are

recommended to reduce air turbulence and maximize efficiency.

No more than 20 degrees (about 4 in. per running ft) of

expansion should be used on each side of the transition fitting.

Turning Vanes

If the Perfect Air

t

Purifier is installed adjacent to a 90 degree

duct elbow, turning vanes should be added inside duct to

improve air distribution across the face of the air purifier.

Electrical Power

The Perfect Air

t

Purifier should only be powered when airflow

is present. The furnace control EAC terminals provide power

only when the furnace blower is operating. Perfect Air

t

Purifier models GAPAAXBB1625 and GAPAAXBB2025 are

designed to be powered from the electronic air cleaner (EAC)

terminals on a furnace electronic control. If EAC terminals are

not available, an alternative airflow sensing mechanism must be

used to ensure the Perfect Air

t

Purifier is only powered when

airflow is present. Contact local Bryant distributor for

information on approved alternatives.

Door (x1)

Cabinet (x1)

Enhancement Module (x1)

Safety Screen (x1)

Installation Manual

Duct Gasket Tape

(1 roll)

Furnace Adapters (x2)

Return Duct Adapters:
Long (x2) / Short (x2)

Air Purification Cartridge (x1)

(x2)

(x2)

(x1)

(x1)

(x2)

Installation Components

(in bag attached to power cord)

A06064

Fig. 2 -- Perfect Air

t

Purifier Components

GAP

A

Содержание AIRT PURIFIER

Страница 1: ...ptured particles are killed by electrical current flow and ion bombardment A06054 Fig 1 GAPA Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information or as...

Страница 2: ... If the return air duct or furnace openings do not fit the Perfect Air t Purifier cabinet openings gradual transitions are recommended to reduce air turbulence and maximize efficiency No more than 20 degrees about 4 in per running ft of expansion should be used on each side of the transition fitting Turning Vanes If the Perfect Airt Purifier is installed adjacent to a 90 degree duct elbow turning ...

Страница 3: ...of the Perfect Airt Purifier should be readily accessible Enough room should be provided for periodic replacement of the air purifier cartridges ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should install the Perfect Airt Purifier A thorough check of the unit installation should be complete...

Страница 4: ...abinet between the furnace and return air duct see Fig 4 A transition duct may be required e Furnace adapters have been included for installer convenience They are designed for top or bottom mount installations see Fig 5 f Return air duct adapters have been included for installer convenience They should be used to connect the upstream side of the air purifier cabinet to the return air duct see Fig...

Страница 5: ...ply connector see Fig 7 d Route the power cord through nearest cabinet hole and protect with enclosed cable connector Zip ties have been enclosed to secure the power cord to the side of the power supply e Attach the quick connect terminals to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring to furnace chassis ground NOTE The Perfect Airt Purifier is to be powered by 115v 60 Hz ...

Страница 6: ...s the safety switch is activated b Turn the HVAC system power on and adjust the thermostat or Evolutiont System Control to activate the system fan c Turn the Perfect Airt Purifier power switch to on position d The power indicator light above the Air Purifier power switch should illuminiate see Fig 8 e Check to ensure the light goes off when the Perfect Airt Purifier power switch is set to off when...

Страница 7: ...e electrical components Disconnect power between checks and then proceed carefully WARNING The Perfect Airt Purifier is equipped with a power indicator light located on the door see Fig 8 This power indicator light will illuminate when the Perfect Airt Purifier door is installed the power switch is in the on position AND the furnace blower is running If the power indicator light is not illuminated...

Страница 8: ... EAC terminals 115v 60 Hz from furnace EAC terminals Maximum Airflow CFM 1600 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPBBCAR1625 GAPBBCAR2025 Dimensions GAPAAXBB1625 GAPAAXBB2025 A 18 3 8 21 7 8 B 15 1 8 18 5 8 C 11 1 8 11 1 8 D 17 1 2 21 E 22 1 8 22 1 8 F 25 1 4 25 1 4 7 16 Typical Top Bottom 1 3 16 1 3 16 1 3 16 1 15 16 A C E F B D A06069 Fig 10 Dimens...

Страница 9: ...to the distributor through a registered servicing dealer for credit 4 All work shall be performed during normal working hours LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN AND APPLIES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW...

Страница 10: ...or change at any time specifications or designs without notice and without incurring obligations EBryant Heating Cooling Systems 7310 W Morris St Indianapolis IN 46231 Printed in China Edition Date 3 06 Replaces II GAPA 0 1 Catalog No II GAPA 0 2 GAPA ...

Отзывы: