background image

7

Step 1

Turn the heating and cooling system off.

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury or death.
Before installing or servicing system, always turn off

main power to system. There may be more than one (1)

disconnect switch.

!

WARNING

Step 2

Turn the Perfect Air

t

Purifier switch to the off

position.

Step 3

Remove the Perfect Air

t

Purifier door.

Step 4

Slide out the old air purifier cartridge and discard.

Step 5

Install the new air purifier cartridge.

NOTE

: Make sure that the arrows on the air purifier cartridge

point toward the furnace. This should be in the same direction as
airflow.

Step 6

Replace the Perfect Air

t

Purifier door.

Step 7

Turn the Perfect Air

t

Purifier switch to the on

position.

Step 8

Turn on the heating and cooling system.

Door Switch Magnet

A06066

Fig. 9 -- Door Switch Magnet

TROUBLESHOOTING

SAFETY HAZARD

Failure to follow this caution may result in personal

injury or equipment damage.
The following instructions are for use by qualified

personnel only.

CAUTION

!

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury

or death.
The

following procedures will

expose electrical

components. Disconnect power between checks and then

proceed carefully.

!

WARNING

The Perfect Air

t

Purifier is equipped with a power indicator

light located on the door (see Fig. 8). This power indicator light

will illuminate when the Perfect Air

t

Purifier door is installed,

the power switch is in the on position, AND the furnace blower

is running. If the power indicator light is not illuminated, follow

the troubleshooting steps below.

Step 1

Check that the Perfect Air

t

Purifier door is installed.

NOTE

: A magnet in the door (see Fig. 9) is used to activate a safety

switch in the power supply when the door is installed. The power
supply will not energize the air purifier unless the safety switch is
activated.

Step 2

Check that the Perfect Air

t

Purifier power switch is in

the on (closed) position.

Step 3

Confirm that the furnace blower is operating.

NOTE

: Power will not be supplied to the Perfect Air

t

Purifier

from the furnace controls EAC terminals unless the blower is
running.

Step 4

Confirm that power provided from the furnace control

EAC terminals is being conducted through the wiring to the
Perfect Air

t

Purifier power supply.

Step 5

If all of the above steps are completed and the power

indicator light is still not illuminating, replace the power supply
on the enhancement module. Note that there are no serviceable
parts within the power supply.

GAP

A

Содержание AIRT PURIFIER

Страница 1: ...ptured particles are killed by electrical current flow and ion bombardment A06054 Fig 1 GAPA Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information or as...

Страница 2: ... If the return air duct or furnace openings do not fit the Perfect Air t Purifier cabinet openings gradual transitions are recommended to reduce air turbulence and maximize efficiency No more than 20 degrees about 4 in per running ft of expansion should be used on each side of the transition fitting Turning Vanes If the Perfect Airt Purifier is installed adjacent to a 90 degree duct elbow turning ...

Страница 3: ...of the Perfect Airt Purifier should be readily accessible Enough room should be provided for periodic replacement of the air purifier cartridges ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should install the Perfect Airt Purifier A thorough check of the unit installation should be complete...

Страница 4: ...abinet between the furnace and return air duct see Fig 4 A transition duct may be required e Furnace adapters have been included for installer convenience They are designed for top or bottom mount installations see Fig 5 f Return air duct adapters have been included for installer convenience They should be used to connect the upstream side of the air purifier cabinet to the return air duct see Fig...

Страница 5: ...ply connector see Fig 7 d Route the power cord through nearest cabinet hole and protect with enclosed cable connector Zip ties have been enclosed to secure the power cord to the side of the power supply e Attach the quick connect terminals to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring to furnace chassis ground NOTE The Perfect Airt Purifier is to be powered by 115v 60 Hz ...

Страница 6: ...s the safety switch is activated b Turn the HVAC system power on and adjust the thermostat or Evolutiont System Control to activate the system fan c Turn the Perfect Airt Purifier power switch to on position d The power indicator light above the Air Purifier power switch should illuminiate see Fig 8 e Check to ensure the light goes off when the Perfect Airt Purifier power switch is set to off when...

Страница 7: ...e electrical components Disconnect power between checks and then proceed carefully WARNING The Perfect Airt Purifier is equipped with a power indicator light located on the door see Fig 8 This power indicator light will illuminate when the Perfect Airt Purifier door is installed the power switch is in the on position AND the furnace blower is running If the power indicator light is not illuminated...

Страница 8: ... EAC terminals 115v 60 Hz from furnace EAC terminals Maximum Airflow CFM 1600 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPBBCAR1625 GAPBBCAR2025 Dimensions GAPAAXBB1625 GAPAAXBB2025 A 18 3 8 21 7 8 B 15 1 8 18 5 8 C 11 1 8 11 1 8 D 17 1 2 21 E 22 1 8 22 1 8 F 25 1 4 25 1 4 7 16 Typical Top Bottom 1 3 16 1 3 16 1 3 16 1 15 16 A C E F B D A06069 Fig 10 Dimens...

Страница 9: ...to the distributor through a registered servicing dealer for credit 4 All work shall be performed during normal working hours LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN AND APPLIES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW...

Страница 10: ...or change at any time specifications or designs without notice and without incurring obligations EBryant Heating Cooling Systems 7310 W Morris St Indianapolis IN 46231 Printed in China Edition Date 3 06 Replaces II GAPA 0 1 Catalog No II GAPA 0 2 GAPA ...

Отзывы: