33
CONDENSER ONLY RATINGS* CONTINUED
SST
° F (° C)
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
55 (12.78)
65 (18.33)
75 (23.89)
85 (29.44)
95 (35.0)
105 (40.56)
115 (46.11)
125 (51.67)
113AN(A,W)042---C
30
(---1.11)
TCG
38.00
36.00
33.90
31.90
29.70
27.60
25.30
22.90
SDT
73.20
82.30
91.40
100.60
109.80
119.10
128.40
137.70
KW
1.95
2.20
2.48
2.80
3.14
3.53
3.95
4.41
35
(1.67)
TCG
41.90
39.70
37.40
35.10
32.80
30.50
28.00
25.50
SDT
74.80
83.70
92.80
101.90
111.00
120.20
129.40
138.60
KW
1.97
2.22
2.50
2.81
3.16
3.54
3.97
4.43
40
(4.44)
TCG
46.00
43.60
41.10
38.70
36.20
33.60
30.90
28.10
SDT
76.40
85.20
94.20
103.20
112.20
121.30
130.40
139.50
KW
1.98
2.23
2.52
2.83
3.18
3.56
3.98
4.44
45
(7.22)
TCG
50.30
47.70
45.10
42.40
39.60
36.80
33.90
30.90
SDT
78.10
86.90
95.70
104.60
113.50
122.50
131.40
140.40
KW
2.01
2.26
2.54
2.85
3.19
3.58
4.00
4.45
50
(10.0)
TCG
54.90
52.10
49.20
46.20
43.20
40.20
37.00
33.60
SDT
80.00
88.60
97.20
106.00
114.80
123.70
132.50
141.30
KW
2.03
2.28
2.56
2.87
3.21
3.60
4.01
4.47
55
(12.78)
TCG
59.70
56.60
53.40
50.20
46.90
43.50
40.10
36.40
SDT
81.90
90.30
98.90
107.50
116.20
124.90
133.60
142.20
KW
2.06
2.30
2.58
2.89
3.23
3.62
4.03
4.48
113AN(A,W)048---E
30
(---1.11)
TCG
41.10
38.90
36.70
34.40
32.10
29.70
27.20
24.50
SDT
73.80
83.00
92.30
101.60
111.00
120.40
129.70
139.10
KW
2.19
2.46
2.76
3.10
3.47
3.87
4.30
4.76
35
(1.67)
TCG
45.20
42.80
40.50
38.00
35.50
32.90
30.20
27.40
SDT
75.30
84.40
93.70
102.90
112.20
121.50
130.80
140.00
KW
2.22
2.49
2.79
3.13
3.50
3.90
4.34
4.81
40
(4.44)
TCG
49.60
47.10
44.50
41.90
39.20
36.40
33.50
30.40
SDT
76.90
86.00
95.10
104.30
113.40
122.60
131.80
141.00
KW
2.24
2.51
2.82
3.15
3.53
3.93
4.38
4.85
45
(7.22)
TCG
54.30
51.60
48.80
46.00
43.10
40.10
36.90
33.60
SDT
78.50
87.50
96.60
105.70
114.70
123.80
132.90
142.00
KW
2.27
2.54
2.85
3.19
3.56
3.97
4.41
4.89
50
(10.0)
TCG
59.30
56.40
53.40
50.30
47.10
43.90
40.50
36.90
SDT
80.20
89.20
98.10
107.10
116.10
125.10
134.10
143.00
KW
2.30
2.58
2.88
3.22
3.59
4.00
4.45
4.92
55
(12.78)
TCG
64.60
61.40
58.10
54.80
51.40
47.90
44.20
40.30
SDT
82.10
91.00
99.80
108.70
117.50
126.40
135.20
144.00
KW
2.34
2.61
2.92
3.25
3.63
4.04
4.48
4.96
113AN(A,W)060---G
30
(---1.11)
TCG
54.90
51.90
49.00
46.00
42.90
39.80
36.50
33.10
SDT
77.60
86.40
95.30
104.20
113.20
122.20
131.20
140.20
KW
2.73
3.07
3.45
3.88
4.34
4.85
5.41
6.01
35
(1.67)
TCG
60.30
57.10
53.90
50.70
47.30
43.90
40.30
36.50
SDT
79.50
88.20
97.00
105.80
114.70
123.60
132.50
141.30
KW
2.79
3.13
3.51
3.94
4.40
4.92
5.48
6.08
40
(4.44)
TCG
66.00
62.60
59.10
55.50
51.90
48.20
44.30
40.10
SDT
81.60
90.20
98.80
107.50
116.30
125.00
133.80
142.50
KW
2.86
3.20
3.58
4.00
4.47
4.98
5.54
6.15
45
(7.22)
TCG
72.10
68.30
64.50
60.70
56.70
52.60
48.40
43.80
SDT
83.80
92.20
100.70
109.30
117.90
126.50
135.10
143.60
KW
2.93
3.27
3.65
4.08
4.54
5.06
5.61
6.21
50
(10.0)
TCG
78.50
74.40
70.20
66.00
61.60
57.20
52.50
47.50
SDT
86.10
94.40
102.70
111.20
119.60
128.10
136.50
144.80
KW
3.01
3.35
3.73
4.15
4.62
5.13
5.68
6.27
55
(12.78)
TCG
85.10
80.60
76.10
71.40
66.70
61.80
56.70
51.20
SDT
88.60
96.60
104.80
113.10
121.40
129.70
137.90
146.00
KW
3.09
3.44
3.81
4.24
4.70
5.21
5.75
6.34
* ARI listing applies only to systems shown in Combination Ratings table.
KW
--- Outdoor Unit Kilowatts Only.
SDT
--- Saturated Temperature Leaving Compressor (° F/° C)
SST
--- Saturated Temperature Entering Compressor (° F/° C)
TCG
--- Gross Cooling Capacity (1000 Btuh)
113A