background image

Fig. 12—Typical 24-v Circuit Connections using Bryant Model 2S Thermostat

with FK4C Fan Coil and Smart Staging

A97405

24 VAC HOT

R

G

W/W1

Y/Y2

Y/Y2

Y1/W2

R

DH

RVS COOLING

C

B

L

S1

S2

Y

W2

BRYANT

PROGRAMMABLE

THERMOSTAT

MODEL 2S

FK4C

FAN COIL

 HEAT 
PUMP

G

O

O/W2

W2

Y1

C

W1

R

O

24 VAC COMM

HEAT STAGE 2

HEAT STAGE 3

COOL/HEAT
STAGE 1

FAN

RVS HEATING

TROUBLE

OUTDOOR
SENSOR
CONNECTION

C

J1 JUMPER

REMOVE

J2 JUMPER

FOR HEAT

STAGING

Smart Sequencing Application:  Model 2S thermostat with 
switch C OFF and switch D ON uses single-speed heat pump, 
FK4 fan coil with selected 2:1 size ratio heaters.  Provides 3 
stages of auxiliary heat for even heating comfort via W/W1 
and Y1/W2.  Refer to FK4 Installation Instructions.

Fig. 11—Typical 24-v Circuit Connections using Bryant Model DF Thermostat with Single- or 2-Stage Furnace

A97401

G

R

Y/Y2

O/W2

BRYANT

DUAL FUEL

THERMOSTAT

MODEL DF

SINGLE-STAGE

FURNACE

HEAT PUMP

G

Y

W

C

Y

R

O

W2

Y1/W2

C

B

L

S1

S2

R

C

FURNACE

COMPRESSOR

 FAN

24 VAC HOT

24 VAC COM

N/A

RVS HEATING

RVS SENSING

OUTDOOR
SENSOR
CONNECTION

OUTDOOR
TEMPERATURE
SENSOR

W/W1

See note 7

RVS COOLING

G

R

Y/Y2

O/W2

BRYANT

DUAL FUEL

THERMOSTAT

MODEL DF

TWO-STAGE OR

VARIABLE SPEED

FURNACE

HEAT PUMP

G

C

Y

R

O

W2

Y1/W2

C

B

L

S1

S2

R

C

O

W2

Y1

FURNACE LO

COMPRESSOR

 FAN

24 VAC HOT

24 VAC COM

FURNACE HI

RVS HEATING

RVS SENSING

OUTDOOR
SENSOR
CONNECTION

OUTDOOR
TEMPERATURE
SENSOR

W/W1

W/W1

Y/Y2

See notes 7 and 8

RVS COOLING

A97402

—8—

Содержание 663C

Страница 1: ...r installation of equipment 1 Locate unit away from windows patios decks etc where unit operation sounds may disturb customer 2 Ensure that vapor and liquid tube diameters are appropriate to capacity...

Страница 2: ...ing mode is 66 F V ELEVATE UNIT CAUTION Accumulation of water and ice in base pan may cause equipment damage In areas where prolonged freezing temperatures are encountered elevate unit per local clima...

Страница 3: ...1 for field tubing equivalent line length Refer to Table 2 for accessory requirements For buried line applications greater than 36 in refer to Table 2 and Residential Split System Buried Line Applicat...

Страница 4: ...AND RECOMMENDED LIQUID AND VAPOR TUBE DIAMETERS IN UNIT SIZE LIQUID VAPOR VAPOR LONG LINE Connection Diameter Tube Diameter Connection Diameter Tube Diameter Connection Diameter Tube Diameter 018 3 8...

Страница 5: ...afety glasses protective clothing and gloves when handling refrigerant and observe the following Back seating service valves are not equipped with Schrader valves Fully back seat counter clockwise val...

Страница 6: ...P FA FB FC FD FF FH FAN COIL HEAT PUMP G Y1 W2 L R O INDOOR FAN HEAT STAGE 2 COOL HEAT STAGE 1 NOT USED 24 VAC COM NOT USED TROUBLE OPTIONAL OUTDOOR SENSOR CONNECTION Y C C IF AVAILABLE A97372 24 VAC...

Страница 7: ...R C W2 Y G R C RVS COOLING C W2 OTHER HP THERMOSTAT FA FB FC FD FF FH FAN COIL HEAT PUMP G O E W2 E W3 R Y 24 VAC COM HEAT STAGE 2 COOL HEAT STAGE 1 INDOOR FAN EMERGENCY HEAT O IF AVAILABLE A97373 24...

Страница 8: ...xiliary heat for even heating comfort via W W1 and Y1 W2 Refer to FK4 Installation Instructions Fig 11 Typical 24 v Circuit Connections using Bryant Model DF Thermostat with Single or 2 Stage Furnace...

Страница 9: ...ONNECTION CUT JW1 SHR SHR ODT A97407 24 VAC HOT R G W W1 Y Y2 O W2 RVS COOLING C B S1 S2 BRYANT PROGRAMMABLE THERMOSTAT MODEL HP FA FB FC FH FAN COIL WITH SMART HEAT HEAT PUMP Y1 W2 L R C Y G O W2T W3...

Страница 10: ...VAC COM HEAT STAGE 2 CUT JW1 SHR SHR FA FB FC FH FAN COIL SMART HEAT ODT A97410 24 VAC HOT R C Y G O RVS COOLING W2 OTHER HP THERMOSTAT FA FB FC FH FAN COIL SMART HEAT HEAT PUMP E R C Y G O W2T W3 W2D...

Страница 11: ...rewdriver immediately otherwise control will terminate normal 10 minute defrost cycle in approximately 2 sec NOTE Length of defrost cycle is dependent on the length of time it takes to remove screwdri...

Страница 12: ...rging is necessary during heating season charge must be weighed in accordance with unit rating plate 0 6 oz ft of 3 8 in liquid line above or below 15 ft respectively EXAMPLE To calculate additional c...

Отзывы: