61
APPENDIX I. MODEL NUMBER NOMENCLATURE
−
VERTICAL
Model
J - Puron
®
(R-410A) Refrigerant
Unit Type
580 - Gas Heat RTU
Packaging & 2-Speed Indoor Fan Motor
A = Standard Packaging
D = Standard Packaging & 2-speed indoor
fan
motor
Cooling Tons (Vertical Air Flow Models Only)
17 = 15 tons
20 = 17.5 tons
24 = 20 tons
28 = 25 tons
30 = 27.5 tons
Heat Level Input
220 = 220,000
310 = 310,000
400 = 400,000
Indoor Fan Options (Vertical Air Flow Models Only)
1 = Standard Static/Vertical Supply, Return Air Flow
2 = Medium Static/Vertical Supply, Return Air Flow
3 = High Static/Vertical Supply, Return Air Flow
B = Medium Static High Efficiency Motor/Vertical Supply,
Return Air Flow
C = High Static High Efficiency Motor/Vertical Supply,
Return Air Flow
Refrig. System/Gas Heat Options
D = Two stage compressor with Aluminum gas heat
exchanger
F = Two stage compressor with Stainless Steel gas heat
exchanger
K = Two Stage Cooling with Aluminum gas heat exchanger
and Perfect Humidity™ (only available on 17-28 sizes
with RTPF coil models)
M = Two Stage Cooling with Stainless Steel gas heat
exchanger and Perfect Humidity™ (only available on
17-28 sizes with RTPF coil models)
Novation Coil Only (Outdoor - Indoor - Hail Guard)
G = Al/Al - Al/Cu
H = Al/Al - Cu/Cu
J = Al/Al - E-coat Al/Cu
K = E-coat Al/Al - Al/Cu
L = E-coat Al/Al - E-coat Al/Cu
T = Al/Al - Al/Cu — Louvered Hail Guards
U = Al/Al - Cu/Cu — Louvered Hail Guards
V = Al/Al - E-coat Al/Cu — Louvered Hail Guards
W = E-coat Al/Al - Al/Cu — Louvered Hail Guards
X = E-coat Al/Al - E-coat Al/Cu — Louvered Hail Guards
Round Tube Plate Fin (RTPF) Coil Options
(Outdoor - Indoor - Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu - Al/Cu — Louvered Hail Guards
N = Precoat Al/Cu - Al/Cu — Louvered Hail Guards
P = E-coat Al/Cu - Al/Cu — Louvered Hail Guards
Q = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail Guards
R = Cu/Cu - Al/Cu — Louvered Hail Guards
S = Cu/Cu - Cu/Cu — Louvered Hail Guards
Voltage
E = 460-3-60
P = 208/230-3-60
T = 575-3-60
Outdoor Air Options
A = None
B = Temperature Economizer w/ Barometric Relief
D = Temperature Economizer w/ PE (cent)
H = Enthalpy Economizer w/ Barometric Relief
J = Enthalpy Economizer w/ PE (cent)
P = Manual Outdoor Air Damper
Q = 2 Position Damper
U = Temp Ultra Low Leak Economizer w/ Baro Relief
V = Temp Ultra Low Leak Economizer w/ PE (cent)
W = Enthalpy Ultra Low Leak Economizer w/ Baro Relief
X = Enthalpy Ultra Low Leak Economizer w/ PE (cent)
Example:
Position:
5
8
0
J
E
1
7
D
3
1
0
G
1
A
0
A
A
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17
Factory Installed Options
0A = None
NOTE:
See the 580J 15 to 27.5 ton Price Pages for
a complete list of factory installed options.
C13775
Содержание 580J D17
Страница 80: ...80 APPENDIX IV WIRING DIAGRAMS cont C160041 Fig 72 580J D17 D28 Control Diagram 208 230 3 60 460 575 3 60 ...
Страница 81: ...81 APPENDIX IV WIRING DIAGRAMS cont C160042 Fig 73 580J D17 D28 Power Diagram 208 230 3 60 ...
Страница 82: ...82 APPENDIX IV WIRING DIAGRAMS cont C160043 Fig 74 580J D17 D28 Power Diagram 460 3 60 ...
Страница 83: ...83 APPENDIX IV WIRING DIAGRAMS cont C160044 Fig 75 580J D17 D28 Power Diagram 575 3 60 ...
Страница 84: ...84 APPENDIX IV WIRING DIAGRAMS cont C160050 Fig 76 580J D17 D28 Control Diagram with Perfect Humidity ...
Страница 86: ...86 APPENDIX IV WIRING DIAGRAMS cont C160047 Fig 78 580J D17 D28 Power Diagram 460 3 60 with Perfect Humidity ...
Страница 87: ...87 APPENDIX IV WIRING DIAGRAMS cont C160048 Fig 79 580J D17 D28 Power Diagram 575 3 60 with Perfect Humidity ...
Страница 88: ...88 APPENDIX IV WIRING DIAGRAMS cont C160049 Fig 80 RTU OPEN Wiring Diagram ...
Страница 89: ...89 APPENDIX IV WIRING DIAGRAMS cont C160045 Fig 81 RTU OPEN Wiring Diagram with Perfect Humidity ...