background image

OIL INLET 

3

/

8

 IN. DIA

(2 PLCS) BOTH SIDES

ELECTRICAL CONNECTIONS
(TOP) 

1

/

2

 

IN. DIA BOTH SIDES

(BOTTOM) 

7

/

8

 

IN. DIA BOTH SIDES

11 

15

/

16

12 

1

/

16

1

1

2

FLUE
DIAMETER 

F

B

E

M

A

D

J

N

C

B

G

K

H

E

L

P

ALTERNATE OIL INLET
THROUGH SLOTS

REAR VIEW

CLEANOUT
PORTS

END

RETURN

AIR DUCT

CONTROL

BOX

SIDE RETURN
AIR DUCT

CLEANOUT PORTS

CLEANOUT PORTS

A96336

DIMENSIONS (IN.)

UNIT

SIZE

UNIT DIMENSIONS

DUCT

SUPPLY

OPENING

FLUE

DIAMETER

SIDE

RETURN

OPENING*

END (BOTTOM)

RETURN

OPENING

SIDE

RETURN

DUCT SIZE†

END (BOTTOM)

RETURN

DUCT SIZE†

Width

Depth

Height

A

B

C

D

E

F

G

H

J

K

L

M

N

P

060210

26

42-1/2

54-3/4

24

29

7

17-3/4

37-1/4

24-1/8

29-1/16

20-1/4

38-1/4

24-1/4

38-1/4

* Filter rack provides transition from duct to opening size.
† Duct sizes are ID dimensions for slipping over filter rack.

Fig. 7—Dimensional Drawing

—12—

Содержание 363AAP

Страница 1: ...NITY OF THIS OR ANY OTHER APPLIANCE DO NOT ATTEMPT TO START THE BURNER WHEN EXCESS OIL HAS ACCUMULATED WHEN THE FURNACE IS FULL OF VAPOR OR WHEN THE COMBUSTION CHAMBER IS VERY HOT WARNING For use with...

Страница 2: ...r attic installation As this unit may be installed as an upflow or horizontal furnace it may be located in a basement on the same level as area to be heated suspended or in a crawlspace In any case un...

Страница 3: ...g openings Screens used shall not be smaller than 1 4 in mesh and shall be readily accessible for cleaning If free area through a design of louver or grille is known it shall be used in calculating si...

Страница 4: ...chimney is properly lined and sized per the applicable codes Refer to list of codes in Safety Consid erations section II MASONRY CHIMNEY This furnace can be vented into an existing masonry chimney Th...

Страница 5: ...humidifier connection See Fig 9 These terminals are energized with 115v 0 5 amp maximum during any call for heat FILTERS It is NECESSARY THAT ALL FURNACES BE EQUIPPED WITH A FILTER An external filter...

Страница 6: ...SCREW FILTER RACK FILTER ACCESS PANEL REAR OF FURNACE BASE PANEL FLUSH WITH REAR OF FURNACE SIDE FILTER RACK ALIGNMENT FILTER RACK BOTTOM FILTER RACK REAR PANEL REST FLANGE ON TOP OF BOTTOM PANEL FLA...

Страница 7: ...ed with damper The draft regulator should be adjusted after furnace has been firing for at least 10 minutes and stack draft should be measured and set between 0 025 and 0 035 in wc The draft should be...

Страница 8: ...User s Manual FAILURE TO FOLLOW THIS WARNING COULD RESULT IN POSSIBLE DAMAGE TO THIS EQUIPMENT SERIOUS PER SONAL INJURY OR DEATH WARNING Before performing any service functions unless operations spec...

Страница 9: ...dous condition which could lead to bodily harm 15 Before reassembly heat exchanger and combustion cham ber should be inspected to determine if replacement is required After cleaning place combustion c...

Страница 10: ...reduces efficiency of your system causes erratic performance of controls and could result in damage to motor or heating equipment 1 Inspect filters at regular intervals depending upon dirt conditions...

Страница 11: ...0 7 0 8 0 9 1 0 060210 High 2485 2395 2305 2250 2145 2075 1975 1885 1780 1675 Medium 2195 2125 2060 1990 1915 1860 1785 1700 1620 1525 Low 1640 1590 1540 1515 1460 1410 1350 1275 1190 1075 NOTES 1 Air...

Страница 12: ...DUCT CLEANOUT PORTS CLEANOUT PORTS A96336 DIMENSIONS IN UNIT SIZE UNIT DIMENSIONS DUCT SUPPLY OPENING FLUE DIAMETER SIDE RETURN OPENING END BOTTOM RETURN OPENING SIDE RETURN DUCT SIZE END BOTTOM RETUR...

Страница 13: ...Fig 8 Barometric Damper Locations A95117 FIG A FIG G FIG D FIG L FIG B FIG C FIG J FIG H FIG K POOR WRONG WRONG WRONG WRONG WRONG BAROMETRIC DAMPER LOCATIONS GOOD LOCATIONS BAD LOCATIONS 13...

Страница 14: ...ING MUST CONFORM TO CURRENT CSA 22 1 CANADIAN ELECTRICAL CODE PART 1 AND OR LOCAL CODES 3 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATE...

Страница 15: ...fore attempting to put your furnace into operation for the heating season you should perform the following procedures WARNING If you do not follow these instructions exactly a fire or explosion may re...

Страница 16: ...eo based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in our labs can mean increased confidence that really pays divi...

Отзывы: