11
TESTED AHRI COMBINATION RATINGS
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory
www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Bryant database at:
http://cactaxcredits.info/bryant-ratings/hp_ratings_srch.php
Equipment performance calculator can be accessed at:
http://rpmobbry.wrightsoft.com/
Model Number
Indoor Coil Model
Number
Furnace Model Number
AHRI Standard Ratings --- Cooling
Cooling
Capacity
EER
SEER
ID CFM
High
Low
180BNA024****A
FEUI
26,600
15.0
21.0
800
800
180BNA036****B
FEUI
37,000
14.6
20.0
1200
925
180BNA048****A
FEUI
48,000
13.5
18.0
1400
1120
180BNA060****A
FEUI
59,000
13.1
16.7
1750
1400
*
AHRI = Air Conditioning, Heating & Refrigeration Institute
EER
— Energy Efficiency Ratio
SEER
— Seasonal Energy Efficiency Ratio
TDR —
Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause
degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are
equipped with TDR.
UI
—
User Interface
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations
are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are affected.
18