Installation Guide (1.11)

5

The thermocouple (TE) for devices with control
unit is screwed into one of the screw connections
of the mounting ring (ZR).
Set the first modular ring (SR) so that the
thermocouple is in the exhaust gas flow (see
picture opposite).

Check the correct fit of the thermocouple
before putting on the remaining
accumalator ring modules!

Illustr. 7: Position of the thermocouple

Setting the top cast hood

 
The modular accumulator MAS is completed by a casted top hood.
The top cast hood includes a seal packing, which is used to seal off the
smoke pipe.
The enclosed sealing must be glued into the groove of the top stone. To
do this, cut the sealing to fit and wrap the ends with the adhesive tape to
prevent fraying of the sealing (see adjacent picture).
 

Illustr. 8: Sealing

Because of the minimized flow resistance of the accumulator modules, the installation of a flue
limiting device is required!

 
 