Combustion air regulation
For a simple operation the air income is regulated with one single air con-
trol rod. Please heat with the given combustion air regulations. Insufficient
combustion air leads to an increased environmental impact, bad efficiency
and creosote in the stove and the chimney.
Heating operation
We recommend using safety gloves during operation, since the operating
elements become hot. Open the door slowly – this way no turbulences de-
velop, which let flue gases esca.
Flue exhaust/heating during transitional periods
The
IRON DOG
needs sufficient chimney draught for drawing in the com-
bustion air and exhausting the flue gases. It diminishes with rising outside
temperatures and this can lead to problems to start a fire. When outside
temperatures are over 15°C, please check the chimney draught. (for exam-
ple open the door and keep a burning fire lighter at the entry of the flame
channel – flame and flue gases must visibly take off). In case of too little
draught first light kindling and add burning wood when the draught has
been created.