© 2017 Brunner GmbH
Operating Instructions (1.14)
31
Place the EAS in the wall mount box starting from the bottom and let it click in the click lock
above.- Die EAS unten in den Unterputzkasten setzen und oben in den Klickverschluss ein-
rasten lassen.
The message „LBAT“ disappears after touching 'ENTER', if the new battery has sufficient ca-
pacity.
Old and used batteries do not belong into the domestic garbage!
Every time the control unit is cut from the power supply, the combustion air valve is
put in its emergency/security position with the energy of the 9V block battery.
After 7 to 20 times the battery is used. The message „LBAT“ (= Battery is empty)
appears.
In case of regular power failure it is normal that the battery has to be replaced sev-
eral times a year.
8
ERROR MESSAGES
F01
Sensor damage
The thermocouple in combustion chamber is damaged, has a broken wire
or connector damage.
F02
Thermocouple polarity
The thermocouple in combustion chamber has a faulty connection or dam-
age.
Содержание EAS 2
Страница 1: ...Operating Instructions EAS 2 2017...
Страница 2: ...2 Operating Instructions 1 14 2017 Brunner GmbH...
Страница 34: ...34 Operating Instructions 1 14 2017 Brunner GmbH...