background image

 

 

2

Operating Instructions (1.14)

© 2017 Brunner GmbH

 
 

Содержание EAS 2

Страница 1: ...Operating Instructions EAS 2 2017...

Страница 2: ...2 Operating Instructions 1 14 2017 Brunner GmbH...

Страница 3: ...kground illumination 17 1 5 Tone settings 17 1 6 Damper flap operation 18 1 7 Software version 18 1 8 Version of stove parameters 19 1 9 Combustion logger 19 2 Operation during heating processes 21 3...

Страница 4: ...16 1 4 Brightness of background illumination 17 1 5 Tone settings 17 1 6 Damper flap operation 18 1 7 Software version 18 1 8 Version of stove parameters 19 1 9 Combustion logger 19 2 Operation durin...

Страница 5: ...2017 Brunner GmbH Operating Instructions 1 14 5 7 Changing the battery 29 8 Error messages 31 9 Cleaning 33...

Страница 6: ...rules and regulations of building law must be observed and followed This fireplace is subject to the provisions of 1 BlmSchV Necessary national and European standards and local regulations must be ob...

Страница 7: ...t is available for additional switching functions as the automatic switching of combustion gas flow heat up flap or deactivation of a kitchen hood The relevant additional function has been selected an...

Страница 8: ...ing Instructions 1 14 2017 Brunner GmbH 1 Hint symbols 5 Button status 2 Small numeric dis play 6 Buttons 3 Big numeric dis play 7 Damper flap status 4 Combustion cycle graphic 8 Unit of indicated mea...

Страница 9: ...v en time default 15 minutes Start the fire again Use appropriate fire starting aids like Fidibus sticks do not use fire starting aids in form of fluids Use small pieces of wood for starting fire Comb...

Страница 10: ...of the heating installation is unfavorable S The prolonged combustion mode is active This setting can be useful for avoiding reducing the charcoal build up during combustion Eco off The messages for...

Страница 11: ...tery must be changed im mediately in a correct way Without correctly inserted battery the emergency function cannot be ensured Big numeric display 3 with the relevant unit of measurement 8 The big num...

Страница 12: ...12 Operating Instructions 1 14 2017 Brunner GmbH Button status 5 When a button is pressed the following symbol is shown...

Страница 13: ...ed settings see following table to leave the User menu Menu overview Small numeric display Meaning possible indications S prolonged combustion mode 0 off 1 on KO Eco mode 0 off 1 on DISP Display brigh...

Страница 14: ...L1 NAL2 AHF1 AHF2 HEF1 HEF2 BET1 BET2 OHE1 OHE2 Combustion logger Information about com bustion performance Information display Damper flap status 7 The position of a connected optional damper flap is...

Страница 15: ...blinking in the big numeric display select 1 or 0 with the arrow buttons press ENTER to confirm to leave the menu press the ESC button Factory setting S 0 1 on the S function is active The following h...

Страница 16: ...with the arrow buttons press ENTER to confirm to leave the menu press the ESC button Factory setting Eco 1 0 off the ECO function is not active The following hint symbol is dis played 1 on the ECO fun...

Страница 17: ...he selected value by pressing the ENTER button close the settings by pressing the ESC button Factory setting 80 1 5 TONE SETTINGS The loudness of hint and error messages can be set here 2 loud 1 qui e...

Страница 18: ...rrow buttons press ENTER to confirm to leave the menu press the ESC button Factory setting DROS 1 0 off function deactivated Summer mode 1 on function activated Winter mode Display status depends on t...

Страница 19: ...es as an overview of combustion performance The combustion logger is a generic term for the following indications Small numeric display Explanations Values ABR1 Combustion counter 1 999 how often the...

Страница 20: ...ustion error counter 1 999 how often a combustion error happened 1 to 999 HEF2 Combustion error counter Combustion error counter thousands 1 999 how often a combustion error happened 1 000 to 999 000...

Страница 21: ...ATING PROCESSES During normal heating processes no operation at the display of the EAS is necessary The control unit starts automatically the process when the firing door of the heating insert is open...

Страница 22: ...r lighting fire Close the firing door From now on the EAS takes over the control of the combustion air valve damper flap Closing the door is the signal for the EAS that a heating procedure is started...

Страница 23: ...ing concept re quires that load after load is burned and not log after log When END is displayed in the combustion cycle graphic there are still some hot embers left from the last combustion cycle The...

Страница 24: ...ll wait for a new combustion cycle to begin Error messages will be shown if the re loaded wood amount is too small or when no wood is reloaded at all Therefore avoid unnecessary opening of the stove d...

Страница 25: ...e operating tool clockwise until the stop This is the starting up position AUF For closing the combustion air turn the tool against clockwise un til the stop This is the position of glow keeping ZU Il...

Страница 26: ...flow strongly on the wood in order to heat up fast Load some chopped firewood loosely into the fireplace Load the desired amount of wood logs on this small wood Put a good fire starter such as Fidibus...

Страница 27: ...fuel on the glow bed the fuel is warmed up and the contained humidity is driven out and evaporates This leads to a temper ature reduction in the combustion chamber The volatile fuel components driven...

Страница 28: ...en into the 100 open position The energy necessary for this emergency function comes from a battery which must be inserted in the EAS and ready for use A possibly existing heating up flap or the like...

Страница 29: ...ignal takes place for security reasons a possibly started fire will be finished in the Stage 1 position 7 CHANGING THE BATTERY A necessary battery change is indicated by the message LBAT into the smal...

Страница 30: ...the EAS in the electrical box can be loosened Lead the tool above behind the glass plate into the outer mating planned for it A light pressure unlocks the click lock The EAS can be taken out of the w...

Страница 31: ...mestic garbage Every time the control unit is cut from the power supply the combustion air valve is put in its emergency security position with the energy of the 9V block battery After 7 to 20 times t...

Страница 32: ...tuator does not respond F21 The damper flap actuator has no reference position F22 The damper flap actuator cannot be properly positioned F23 The damper flap actuator cannot reach its reference positi...

Страница 33: ...3 9 CLEANING Cleaning the glass can be done with commercial glass cleaner Do not spray glass cleaner directly on the glass plate since humidity could arrive on the electronics Moisten a cloth with the...

Страница 34: ...34 Operating Instructions 1 14 2017 Brunner GmbH...

Страница 35: ...Operating Instructions 1 14 35 Ulrich Brunner GmbH Zellhuber Ring 17 18 D 84307 Eggenfelden Tel 49 0 8721 771 0 Fax 49 0 8721 771 100 Email info brunner de Latest instructions available on www brunne...

Отзывы: