S A F E T Y

Warning Labels

Besides the dangers described above, there can also be hazardous situations caused
by the sample material. Depending on the type of hazardous substances you work with,
you have to observe specific substance-relevant safety instructions. Put on the corre-
sponding warning label on the appropriate spectrometer position. The label must be
legible and permanently discernible. The following list contains some examples of haz-
ardous substances: 

C a u t i o n   -   F r o s t b i t e

This warning symbol indicates cryogenic materials (e.g. liquid nitrogen)
required to operate the spectrometer (e.g. cooling detector). Skin contact
with these liquids or cooled components causes severe frostbite. Always
handle the liquids with utmost care. Observe the safety instructions for
handling of cryogenic liquids.

C a u t i o n   -   H a r m f u l   M a t e r i a l

This warning symbol indicates the existence of harmful or irritant material
(e.g. the window material BaF

2

). Observe the safety instructions on the

packaging, and the safety data sheets attached. Non-observance may
cause personal injury.

C a u t i o n   -   T o x i c   M a t e r i a l

This warning symbol indicates the existence of toxic material (e.g. the win-
dow material KRS-5). Observe the safety instructions on the packaging,
and the safety data sheets attached. Non-observance may cause severe
personal injury or even death.

C a u t i o n   -   I n f e c t i o u s   M a t e r i a l

This warning symbol indicates the possible presence of bio-hazardous and
infectious material. When working with this kind of material always, observe
the prevailing laboratory safety regulations and take all necessary precau-
tions and disinfection measures (e.g. wearing protective clothing, masks,
gloves etc.). Failure to do so may cause severe personal injury or even
death. (For information on how to use, dilute and efficiently apply disinfec-
tants, refer to the 

Laboratory Biosafety Manual: 1993

 by WHO - World

Health Organization.)

C a u t i o n   -   R a d i o a c t i v e   M a t e r i a l

This warning symbol indicates the possible presence of radioactivity. When
working with radioactive material, always observe the safety regulations
and take all necessary protective measures (e.g. wearing protective cloth-
ing, masks gloves etc.). Failure to do so may cause severe personal injury
or even death.

Содержание VERTEX 70v

Страница 1: ...User Manual 1007253 VERTEX 70v...

Страница 2: ...rand names registered trademarks etc used in this manual even if not explicitly marked as such are not to be considered unprotected by trademarks law They are the property of their respective owner Th...

Страница 3: ...ion 19 External Components 20 Internal Components 25 Optical Path 29 5 Operation 31 General Information 31 Switching VERTEX 70v On and Off 31 QuickLock 33 Automatic Accessory Recognition 35 Performing...

Страница 4: ...awings 109 E Connecting VERTEX 70v to PC 115 General Information 115 Possible Connection Topologies 116 Selecting Network Addresses 119 Assigning Network Addresses 120 Checking the Connection 123 F El...

Страница 5: ...ures described in this manual Never remove or deactivate any supporting safety systems during spectrometer opera tion Ensure that objects and or material not required for the measurement is out of the...

Страница 6: ...tions and follow the precautions described to avoid personal injury and or property damage Caution Electrical Shock This warning symbol indicates electrical hazard The symbol is located near live part...

Страница 7: ...ty data sheets attached Non observance may cause personal injury Caution Toxic Material This warning symbol indicates the existence of toxic material e g the win dow material KRS 5 Observe the safety...

Страница 8: ...ons are not taken Warning indicates that death severe personal injury or substantial property damage CAN result if proper precautions are not taken Caution indicates that minor personal injury or prop...

Страница 9: ...hnology ensures a signal transmission free from interfer ences and guarantees the highest signal to noise ratio VERTEX 70v can be controlled by any data system PC workstation notebook etc on which the...

Страница 10: ...water vapor or carbon dioxide are eliminated nearly completely from the spectrometer interior Evacuating the spectrome ter is more efficient than purging it or using desiccant cartridges The result of...

Страница 11: ...sary For detailed information about how to install the computer refer to the PC manual DELIVERY SCOPE The basic instrument of VERTEX 70v allows upgrading with additional components and or accessories...

Страница 12: ...any signs of damage contact your local shipping representative before opening the shipping box Warning Do not put a spectrometer into operation that shows signs of damage Failure to do so may result i...

Страница 13: ...be interrupted for example either by disconnecting the safety plug or switching off the mains switch on the spectrometer rear side or disconnecting the pri mary power receptacle Environmental Requirem...

Страница 14: ...ice life ensure that the fol lowing site requirements are met Do not install the spectrometer near sources of potential inductive electrical interference e g pumps switching motors microwave ovens etc...

Страница 15: ...cord length should not exceed 3m Depending on the local conditions the original power cord may need to be exchanged for a power cord that complies with the standards of the country in question The po...

Страница 16: ...n refer to the computer manual After having set up the data cable connection turn on the spectrometer using the mains switch After a few seconds the spectrometer beeps once and starts a self test Afte...

Страница 17: ...g particles from enter ing the spectrometer together with the influent air Note For detailed information about the vacuum pump refer to the user manual provided by the vacuum pump manufacturer Attachm...

Страница 18: ...stall the supplied sealing ring at the attachment flange See figure 5 Press the supplied flexible metal hose against the attachment flange figure 6a and attach the hose to the flange using the supplie...

Страница 19: ...contact with the table on which the spectrometer is placed During the operation the vacuum pump produces an increased noise level In order to reduce the noise level install the supplied noise reductio...

Страница 20: ...figure 8 and pulling out the plug Connect one end of the hose to your supply line for dry air or dry nitrogen gas and insert the other end of the hose into the purge gas inlet for either the sample co...

Отзывы: