I N S T A L L A T I O N

Delivery Scope

For installing the vacuum pump, the following items are included:

Vacuum pump (including the user manual)

Noise reduction hood

Vibration absorber

2x flexible metal hoses

4x hose clamps

4x sealing rings

O p t i o n a l   C o m p o n e n t s

Depending on the ordered spectrometer configuration, the delivery scope can also
include following optional components:

Optional spectrometer components (e.g. optional detectors) and/or accessories

Optional OPUS software packages (e.g OPUS/STEP) including the corresponding 
manuals

I n s p e c t i n g   t h e   P a c k a g i n g

After the receipt of the spectrometer, inspect the packaging for damages. If there are
any signs of damage, contact your local shipping representative before opening the
shipping box.

Warning: Do not put a spectrometer into operation that shows signs of 

damage. Failure to do so may result in severe personal injuries 
and/or property damage.

T r a n s p o r t a t i o n

Due to its weight (about 105kg), VERTEX 70v has to be carried by at least four persons
using the supplied transport handles. For transportation purposes, attach these handles
properly to the right and left spectrometer side as shown in figure 1 using 12 screws
(M5 x 16). Tighten the screws using a hex kex (size 4mm). After having transported the
instrument to the desired place, you can remove the transport handles again. Alterna-
tively, you can transport the instrument with a fork lifter.

Warning: Due to the high instrument weight, improper transportation can 

lead to personal injuries and/or spectrometer damage.

Содержание VERTEX 70v

Страница 1: ...User Manual 1007253 VERTEX 70v...

Страница 2: ...rand names registered trademarks etc used in this manual even if not explicitly marked as such are not to be considered unprotected by trademarks law They are the property of their respective owner Th...

Страница 3: ...ion 19 External Components 20 Internal Components 25 Optical Path 29 5 Operation 31 General Information 31 Switching VERTEX 70v On and Off 31 QuickLock 33 Automatic Accessory Recognition 35 Performing...

Страница 4: ...awings 109 E Connecting VERTEX 70v to PC 115 General Information 115 Possible Connection Topologies 116 Selecting Network Addresses 119 Assigning Network Addresses 120 Checking the Connection 123 F El...

Страница 5: ...ures described in this manual Never remove or deactivate any supporting safety systems during spectrometer opera tion Ensure that objects and or material not required for the measurement is out of the...

Страница 6: ...tions and follow the precautions described to avoid personal injury and or property damage Caution Electrical Shock This warning symbol indicates electrical hazard The symbol is located near live part...

Страница 7: ...ty data sheets attached Non observance may cause personal injury Caution Toxic Material This warning symbol indicates the existence of toxic material e g the win dow material KRS 5 Observe the safety...

Страница 8: ...ons are not taken Warning indicates that death severe personal injury or substantial property damage CAN result if proper precautions are not taken Caution indicates that minor personal injury or prop...

Страница 9: ...hnology ensures a signal transmission free from interfer ences and guarantees the highest signal to noise ratio VERTEX 70v can be controlled by any data system PC workstation notebook etc on which the...

Страница 10: ...water vapor or carbon dioxide are eliminated nearly completely from the spectrometer interior Evacuating the spectrome ter is more efficient than purging it or using desiccant cartridges The result of...

Страница 11: ...sary For detailed information about how to install the computer refer to the PC manual DELIVERY SCOPE The basic instrument of VERTEX 70v allows upgrading with additional components and or accessories...

Страница 12: ...any signs of damage contact your local shipping representative before opening the shipping box Warning Do not put a spectrometer into operation that shows signs of damage Failure to do so may result i...

Страница 13: ...be interrupted for example either by disconnecting the safety plug or switching off the mains switch on the spectrometer rear side or disconnecting the pri mary power receptacle Environmental Requirem...

Страница 14: ...ice life ensure that the fol lowing site requirements are met Do not install the spectrometer near sources of potential inductive electrical interference e g pumps switching motors microwave ovens etc...

Страница 15: ...cord length should not exceed 3m Depending on the local conditions the original power cord may need to be exchanged for a power cord that complies with the standards of the country in question The po...

Страница 16: ...n refer to the computer manual After having set up the data cable connection turn on the spectrometer using the mains switch After a few seconds the spectrometer beeps once and starts a self test Afte...

Страница 17: ...g particles from enter ing the spectrometer together with the influent air Note For detailed information about the vacuum pump refer to the user manual provided by the vacuum pump manufacturer Attachm...

Страница 18: ...stall the supplied sealing ring at the attachment flange See figure 5 Press the supplied flexible metal hose against the attachment flange figure 6a and attach the hose to the flange using the supplie...

Страница 19: ...contact with the table on which the spectrometer is placed During the operation the vacuum pump produces an increased noise level In order to reduce the noise level install the supplied noise reductio...

Страница 20: ...figure 8 and pulling out the plug Connect one end of the hose to your supply line for dry air or dry nitrogen gas and insert the other end of the hose into the purge gas inlet for either the sample co...

Отзывы: