1.2.2.2 Long Term Storage
1.2.2.2.1 New Pump Long Term Storage
New pumps being stored more than three months time before installation must
adhere to the following procedures:
Notify Vulcan Pumps in writing that the equipment is to be stored more than
three months time prior to installation and the proper long term storage
procedures have been adhered to.
Pumps must be stored in a long term storage crate.
Pumps must be stored in a dry environment at temperatures ranging from
10°C (50°F) to 49°C (120°F), relative humidity must not exceed 60%.
Minimum winding resistance (5 Meg ohms) must be checked every 30 days.
The shaft must be rotated 15 revolutions every 30 days.
1.2.2.2.2 Used Pump Long Term Storage
Used pumps being put into long term storage more than two months time before
installation should adhere to the following procedures:
Pump wet end and motor should be disassembled, cleaned and inspected for
wear and damage.
All originally painted parts should be touched up or repainted.
Pump should be reassembled and stored in an upright position.
WARNING!
Pumps must be stored in a long term storage crate.
Pumps must be stored in a dry environment at temperatures ranging from
10°C (50°F) to 49°C (120°F), relative humidity must not exceed 60%.
Minimum winding resistance (5 Meg ohms) must be checked every 30 days.
The shaft must be rotated 15 times every 30 days.
1.2.2.2.3 Spare Parts Long Term Storage
Spare Parts do not come with rust inhibitor protection for long term storage, unless
specified on the order. New pump parts being stored for more than three months
time before installation must adhere to the following procedures:
Cast and machined wet end parts should be stored in a dry environment
Mechanical Seal Assemblies should be kept sealed in their original packaging
and kept in a dry environment
Elastomer components should be stored in a sealed polyethylene bag, kept in
a dry environment and away from of exposure to UV rays.
DAMAGED PUMP PARTS SHOULD BE REPLACED TO ENSURE SAFE
AND PROPER PERFORMANCE OF THE PUMP!
Содержание Vulcan Pumps HDS 100L
Страница 1: ...Document No A1540 Installation Operation and Maintenance Manual HDS Submersible Pumps Agitator ...
Страница 4: ......
Страница 38: ...AC Submersible Pump Motors Installation Operating Manual 4 09 MN414 ...
Страница 39: ...Any trademarks used in this manual are the property of their respective owners ...
Страница 41: ...Section 1 General Information ii Table of Contents MN414 ...
Страница 50: ...Baldor District Offices ...