Once the pump has found a stable operating condition, monitor the motor amperage draw. If
possible monitor the pump discharge pressure and flow rate. It is recommended that amperage
draw, discharge pressure and flow rate readings be recorded frequently to identify any changes
in the pump performance that could indicate possible problems with the pump or motor.
CAUTION!
CAUTION!
CAUTION!
4.3 Pump
Shut
Down
CAUTION!
Always flush the entire discharge line with clean liquid prior to shutting down the pump.
4.3.1 Pump Standby - Cold Temperature Applications
If the pump is removed from the sump when it is not being used, ensure the following:
1. Drain all of the liquid from the wet end components, water jacket, jet ring and piping.
Water expands when it freezes and can cause damage to equipment.
2. The oil in the motor seal cavity can thicken during standby and some of the elastomers
must not be operated in cold temperatures. Ensure that the pump is pre-heated prior to
start-up.
OPERATING THE PUMP WITHOUT CLEANING OUT THE SUMP PRIOR
TO INSTALLATION MAY CAUSE DAMAGE TO THE PUMP ASSEMBLY!
ALWAYS CALCULATE THE SLURRY SYSTEM OPERATING POINT
PRIOR TO PURCHASING OR INSTALLING A PUMP!
ALWAYS CHECK THE MOTOR AMPERAGE DRAW TO ENSURE THE
MOTOR IS NOT BEING OVERLOADED?
NEVER STOP THE PUMP WHILE SOLIDS ARE IN THE DISHCARGE
PIPE!
Содержание Vulcan Pumps HDS 100L
Страница 1: ...Document No A1540 Installation Operation and Maintenance Manual HDS Submersible Pumps Agitator ...
Страница 4: ......
Страница 38: ...AC Submersible Pump Motors Installation Operating Manual 4 09 MN414 ...
Страница 39: ...Any trademarks used in this manual are the property of their respective owners ...
Страница 41: ...Section 1 General Information ii Table of Contents MN414 ...
Страница 50: ...Baldor District Offices ...