ESC/P Command Reference
- 91 -
5. Control Command Details
ESC iXX2 Specify default character size
ASCII: ESC
i
X
X
2
n1
n2
n3
n4
Decimal: 27 105 88 88 50 n1 n2 n3 n4
Hexadecimal:
1B 69 58 58 32 n1 n2 n3 n4
Parameters
n1: 02h (Fixed)
n2: 00h (Fixed)
00h
≤
n3
≤
FFh, 00h
≤
n4
≤
01h
Description
z
Specifies the default character size.
n3+(n4*256): Default character size (dots)
z
The following settings (dots) are valid.
The maximum valid setting is n=400.
*The manufacturer’s default is 24.
z
This command is a static command.
Remarks
z
Invalid if the setting is a value outside of the allowable range
Содержание RuggedJet RJ-4040
Страница 1: ...Software Developer s Manual ESC P Command Reference RJ 4030 4040 Version 1 0 ...