ESC/P Command Reference
- 95 -
5. Control Command Details
ESC iX(2 Specify default page length
ASCII: ESC
i
X
(
2
n1
n2
n3
n4
Decimal: 27 105 88 40 50 n1
n2 n3 n4
Hexadecimal:
1B 69 58 28 32 n1
n2 n3 n4
Parameters
n1: 02h (Fixed)
n2: 00h (Fixed)
00h
≤
n3
≤
FFh, 00h
≤
n4
≤
2Eh
Description
z
Specifies the default page length.
n3+(n4*256): Default page length (dots) (0, 229 through 11999)
*A default page length of 0 indicates the Auto setting.
*The manufacturer’s default is 0.
z
This command is a static command.
Remarks
z
Invalid if the setting is a value outside of the allowable range
ESC iX(1 Retrieve default page length
ASCII: ESC
i
X
(
1
n1
n2
Decimal: 27
105
88 40
49
n1
n2
Hexadecimal:
1B 69 58 28 31 n1
n2
Parameters
n1: 00h (Fixed)
n2: 00h (Fixed)
Description
z
The default page length setting is returned as 4-byte data.
[1] 02h
(Fixed)
[2] 00h
(Fixed)
[3, 4] n3 n4 settings
n3+(n4*256): Default page length (dots)
*A default page length of 0 indicates the Auto setting.
z
The retrieved value is a value specified by a static command.