![Brother PT-P900W Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/brother/pt-p900w/pt-p900w_software-manual_55156077.webp)
P-touch Template Command Reference
- 71 -
7.
Control Command Details
ESC iXa2 Specify non-printed text strings
ASCII:
ESC i
X a
2 n1 n2 n3 data
Decimal:
27 105 88 97 50 nd1 nd2 nd3 datad
Hexadecimal: 1B 69 58 61 32 nh1 nh2 nh3 datah
Parameters
01h
≤
nh1
≤
15h
nh2: 00h (Fixed)
nh3: 01h (Fixed)
00h
≤
datah
≤
FFh
Description
Specifies the non-printed text string.
nh1+(nh2*256): Length of the text string (0 to 20) + 1
data:
Text string (The maximum number of characters that can be set is 20 characters
(bytes).)
This command is a static command.
Remarks
Invalid if more than 20 characters are specified
Example
To specify the non-printed text string as “ABCD”:
Since the text string contains four characters, nh1=05h and nh2=00h, and then the command will be as
follows.
ESC i X a 2 05h 00h 01h A B C D
(1Bh 69h 58h 61h 32h 05h 00h 01h 41h 42h 43h 44h)