![Brother PT-P900W Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/brother/pt-p900w/pt-p900w_software-manual_55156055.webp)
P-touch Template Command Reference
- 49 -
7.
Control Command Details
^CF
Full cut setting
ASCII:
^
C F n1 n2
Decimal:
94 67 70 nd1 nd2
Hexadecimal: 5E 43 46 nh1 nh2
Parameters
0
≤
n1
≤
9
0
≤
n1
≤
9
Description
Specifies whether or not full cut is used, and specifies the number of copies.
(n1*10)+n2: Full cut and number of copies settings
(00: OFF; 01 to 99: Number of copies) (Default value: 01)
This command is a dynamic command.
Remarks
The full cut label number setting can be between 1 and 99. This command becomes invalid if any other
value has been specified.
Example
To cut after every two labels:
Since the auto cut label number will be set to 2, n1=0 and n2=2. Therefore, the command will be as follows.
^ C F 0 2
(5Eh 43h 46h 30h 32h)