P-touch Template Command Reference
- 50 -
7.
Control Command Details
^CH
Half cut setting
ASCII:
^
C H n
Decimal:
94 67 72 nd
Hexadecimal: 5E 43 48 nh
Parameters
0
≤
n
≤
1
Description
Specifies whether or not half cut is used.
n: Half cut setting
(ON: 1 (default); OFF: 0)
This command is a dynamic command.
Remarks
Invalid if n is a value other than 1 or 0
Example
To make half cuts:
Since half cuts will be enabled, n=1. Therefore, the command will be as follows.
^ C H 1
(5Eh 43h 48h 31h )