9.25 Panel ASSY
(1) Unlock the Connector and disconnect the Flat cable from the Main PCB ASSY.
(2) Remove the one screw (TAPTITE CUP S M3x6) and release the Panel grounding
wire from the Main PCB frame.
Fig. 3-81
(3) Release the four Bosses and remove the Panel ASSY.
Fig. 3-82
TAPTITE CUP S M3x6
Flat cable
Panel ASSY
Panel grounding wire
Connector
Main PCB
Main PCB frame
Pull here to unlock.
Flat cable
ASSY
Connector
Bosses
Bosses
Panel ASSY