![Brother MFC 4550 Скачать руководство пользователя страница 98](http://html.mh-extra.com/html/brother/mfc-4550/mfc-4550_service-manual_53808098.webp)
V –
16
WSW05
(1st dial tone and busy tone detection)
Function
Selector
No.
Setting and Specifications
Max. pause time allowable for
remote ID code detection
Busy tone detection in auto-
matic receiving mode
1st dial tone detection
1
|
3
4
0: 2 seconds
1: 1 second
Busy tone detection in auto-
matic sending mode
No. 1
2
3
0
0
0
:
3.5 sec. WAIT
0
0
1
:
7.0 sec. WAIT
0
1
0
:
10.5 sec. WAIT
0
1
1
:
14.0 sec. WAIT
1
0
0
:
17.5 sec. WAIT
1
0
1
:
21.0 sec. WAIT
1
1
0
:
24.5 sec. WAIT
1
1
1
:
Detection (Without WAIT)
No. 5
6
0
0
:
No detection
0
1
:
Detection only
after dialing
1
0
:
No detection
1
1
:
Detection before
and after dialing
0:
Yes
1:
No
7
5
6
DTMF detection time
NOTE: Selectors 5 through 7 are not applicable in those countries where no busy tone detec-
tion is supported, e.g., U.S.A.
●
Selectors 1 through 3:
1st dial tone detection
These selectors activate or deactivate the 1st dial tone detection function which detects the
1st dial tone issued from the PSTN when a line is connected to the PSTN.
Setting all of these selectors to "1" activates the dial tone detection function so that the
equipment starts dialing upon detection of a dial tone when a line is connected. (However, in
those countries which support no dial tone detection function, e.g. in the U.S.A., setting
these selectors to "1" makes the equipment start dialing after a WAIT of 3.5 seconds.) For
the detecting conditions of the 1st dial tone, refer to WSW07 and WSW08.
Other setting combinations deactivate the dial tone detection function so that the equipment
starts dialing after the specified WAIT (3.5, 7.0, 10.5, 14.0, 17.5, 21.0, or 24.5 seconds) with-
out detection of a dial tone when a line is connected to the PSTN.
●
Selector 4:
Max. pause time allowable for remote ID code detection
This selector sets the maximum pause time allowable for detecting the second digit of a re-
mote ID code after detection of the first digit in remote reception.
If selector 4 is set to "0" (2 seconds), for instance, only a remote ID code whose second digit
is detected within 2 seconds after detection of the first digit will become effective so as to
activate the remote function.
0:
40 ms min. 1:
100 ms min.
8
Содержание MFC 4550
Страница 5: ...CHAPTER I GENERAL DESCRIPTION ...
Страница 14: ...CHAPTER II INSTALLATION ...
Страница 15: ...CONTENTS 1 INSTALLING THE UPDATE DATA TO THE FACSIMILE EQUIPMENT II 1 ...
Страница 18: ...CHAPTER III THEORY OF OPERATION ...
Страница 49: ...CHAPTER IV DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Страница 81: ...CHAPTER V MAINTENANCE MODE ...
Страница 89: ...V 7 Scanning Compensation Data List 200 dpi ...
Страница 133: ...CHAPTER VI ERROR INDICATION AND TROUBLESHOOTING ...
Страница 163: ...MAIN 8 8 FAX3550 3650 8000P 8200P MFC4550 6550MC 7550MC MFC9000 9500 A ...
Страница 185: ...D CONTROL PANEL 1 2 ...
Страница 187: ...E POWER SUPPLY 120 V Low voltage power supply ...
Страница 188: ...E POWER SUPPLY 200 240 V Low voltage power supply European versions ...
Страница 189: ...E POWER SUPPLY 200 240 V Low voltage power supply Asian versions ...
Страница 190: ...E POWER SUPPLY High voltage power supply ...
Страница 191: ...Sept 98 5X52012 Printed in Japan ...