VI –
6
■
Definition of Error Codes on the Communications List
(1) Calling
10
08
Wrong number called.
11
01
No dial tone detected.
11
02
Busy tone detected before dialing.
11
03
2nd dial tone not detected.
11
05
No loop current detected. *
11
06
Busy tone detected after dialing or called.
11
07
No response from the remote station in sending.
11
10
No tone detected after dialing.
17
07
No response from the calling station in receiving.
* Available in Germany and Austria only.
Code 1
Code 2
Causes
(2) Command reception
Code 1
Code 2
Causes
20
01
Unable to detect a flag field.
20
02
Carrier was OFF for 200 ms or longer.
20
03
Abort detected (“1” in succession for 7 bits or more).
20
04
Overrun detected.
20
05
A frame for 3 seconds or more received.
20
06
CRC error in answer back.
20
07
Undefined command received.
20
08
Invalid command received.
20
09
Command ignored once for document setting or for dump-
ing-out at turn-around transmission.
20
0A
T5 time-out error
20
0B
CRP received.
20
0C
EOR and NULL received.
Содержание MFC 4550
Страница 5: ...CHAPTER I GENERAL DESCRIPTION ...
Страница 14: ...CHAPTER II INSTALLATION ...
Страница 15: ...CONTENTS 1 INSTALLING THE UPDATE DATA TO THE FACSIMILE EQUIPMENT II 1 ...
Страница 18: ...CHAPTER III THEORY OF OPERATION ...
Страница 49: ...CHAPTER IV DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Страница 81: ...CHAPTER V MAINTENANCE MODE ...
Страница 89: ...V 7 Scanning Compensation Data List 200 dpi ...
Страница 133: ...CHAPTER VI ERROR INDICATION AND TROUBLESHOOTING ...
Страница 163: ...MAIN 8 8 FAX3550 3650 8000P 8200P MFC4550 6550MC 7550MC MFC9000 9500 A ...
Страница 185: ...D CONTROL PANEL 1 2 ...
Страница 187: ...E POWER SUPPLY 120 V Low voltage power supply ...
Страница 188: ...E POWER SUPPLY 200 240 V Low voltage power supply European versions ...
Страница 189: ...E POWER SUPPLY 200 240 V Low voltage power supply Asian versions ...
Страница 190: ...E POWER SUPPLY High voltage power supply ...
Страница 191: ...Sept 98 5X52012 Printed in Japan ...