LK3-B438E Mark II
19
5-2 . Operating procedure
Program No.
X-scale (%)
Y-scale (%)
Speed (rpm)
Factory default
00 *
100
100
2000
Variable range
01 - 49
20 - 200
20 - 200
1,000 - 2,500
S E L E C T
PROGRAM NO.
COUNTER
X-SCALE
Y-SCALE
SPEED
P
S E L E C T
PROGRAM NO.
COUNTER
X-SCALE
Y-SCALE
SPEED
P
S E L E C T
PROGRAM NO.
COUNTER
X-SCALE
Y-SCALE
SPEED
P
Press the SELECT switch
y
until the PROGRAM NO. in-
dicator illuminates.
Press the DISPLAY SET
switches
!2
until the desired
program number is flashing
in the display window.
Depress the foot switch to
the second step.
* The display will stop flashing
and illuminates steadily, and
the feed mechanism will move
to the sewing start position.
This completes the setting of the pro-
gram number.
1
2
3
Press the SELECT switch
y
until the X-scale or Y-scale
indicator illuminates.
Press the DISPLAY SET
switches
!2
until the de-
sired scale setting is flash-
ing in the display window.
(The setting is displayed as a per-
centage.)
Depress the foot switch to
the second step.
* The display will stop flashing
and illuminates steadily, and
the feed mechanism will move
to the sewing start position.
1
2
3
Press the SELECT switch
y
until the SPEED indicator il-
l u m i n a t e s .
Press the DISPLAY SET
switches
!2
until the de-
sired speed setting is flash-
ing in the display window.
1
2
This completes the setting of the X-scale
or Y-scale.
y
y
y
!2
!2
1st step
2nd step
Preparation
Turn on the power switch.
(The POWER indicator
q
will illuminate and the pro
gram number will flash in the display window
!4
.)
* For checking the origin points for X and Y feed
5-2-1 . Setting the program number
Determine the appropriate program from the program list which is given on pp. 3 - 5.
5-2-2 . Setting the X-scale and Y-scale
5-2-3 . Setting the sewing speed
1st step
2nd step
NOTE:
Be sure to check the sewing pattern
(refer to page 20) after setting has
been completed to make sure that
the needle drops down into the hole
of the button.
5 . OPERATION
!2