2-18
Confidential
4.2
Troubleshooting for Image Defects
4.2.1 Defect examples
Fig. 2-5
4.2.2 Troubleshooting according to image defect
Light
<User Check>
- Check that the contrast setting is not too light.
- Clean the CIS glass.
Step
Cause
Remedy
1
Incorrect white level correction data Execute the maintenance mode function
"Acquire white level data and set CIS scan
area". (Refer to
.)
2
Dirty calibration sheet
Replace the calibration sheet with a new
one.
3
First side or second side CIS unit
failure
Replace the first side or second side CIS
unit.
4
Main PCB failure
Replace the main PCB ASSY.
Содержание ImageCenter ADS-2800W