4-10
Confidential
1.6
Setting Multi Feeding Sensor Threshold
(1) Press and hold the [X] and [to USB] keys simultaneously, and plug the AC power cord
into the outlet. Check that the Power LED and the Error LED are lit, and release these
two keys.
(2) Press the [X], [to USB], [to PC], and [X] keys in this order.
The to Network Device1 LED, to Network Device2 LED, and to Network Device3 LED
flash.
(3) Turn ON the power switch of the computer.
(4) Connect the computer to the machine with the USB cable.
(5) Double-click "brADSmt1.exe" that was copied into the temporary folder to start it.
(6) Select the model name in the [Select model:] box, and click the [Start] button.
The multi feeding sensor threshold is set.
(7) Set the sheet for multi feeding sensor threshold setting in the ADF, and execute the
maintenance mode function "Check ADF".
Refer to "1.3.3 Check ADF" in Chapter 5.
(8) Execute the maintenance mode function "Acquire white level data and set CIS scan
area".
Refer to "1.3.5 Acquire white level data and set CIS scan area" in Chapter 5.
Note:
• For Windows
®
8, right-click "brADSmt1.exe" to display the menu, and select "Run
as an administrator" to start.