![Brother HL-2260 Скачать руководство пользователя страница 148](http://html.mh-extra.com/html/brother/hl-2260/hl-2260_service-manual_53611148.webp)
4-6
Confidential
2. IF YOU REPLACE THE LOW-VOLTAGE
POWER SUPPLY PCB ASSY
What to do after replacement
• Reset Irregular Power Supply Detection Counter of Low-voltage Power Supply PCB
What you need to prepare
None
2.1 Reset Irregular Power Supply Detection Counter of
Low-voltage Power Supply PCB
LED models
Refer to
“1.4.15 Reset irregular power supply detection counter of low-voltage power supply
to reset the irregular power supply detection counter.
LCD models
Refer to
“1.3.20 Reset irregular power supply detection counter of low-voltage power supply