1. MAINTENANCE MODE
The maintenance mode is exclusively designed for the checking, setting and adjustments of
the machine by using the buttons on the control panel. The EEPROM can be customized
according to the destination of the machine. Moreover, the operational check of the LCD,
operation panel board, and sensors, print test, display of the log information and error codes,
and change of the worker switches (WSW) can be performed.
1.1
How to Enter the Maintenance Mode
<Operating Procedure>
(1) Press the
Menu
button and then the
Start
button while the machine is in the ready state.
Next, press the
button four times to enter the maintenance mode.
(2) The machine beeps for one second and displays “
” on the LCD,
indicating that it is placed in the initial state of the maintenance mode, a mode in which
the machine is ready to accept entry from the buttons.
(3) To select any of the maintenance mode functions shown in the
, enter the
maintenance mode that you want to use using the buttons.
1.2
How to Enter the End User-accessible Maintenance Mode
Basically, the maintenance-mode functions listed in the next page should be accessed by
service personnel only. However, you can allow end users to access some of these under the
guidance of service personnel by phone, for example.
The end user-accessible functions are shaded in the table given on the
. (codes
06,
09, 10, 11, 12, 25, 43, 45, 52, 53, 54, 66, 68, 71, 72, 80, 82, 87, 88
and
91
)
Function code 10 accesses the firmware switches, each of which has eight selectors.
The service personnel should instruct end users to follow the procedure given below.
<Operating Procedure>
(1) Press the
Menu
,
Start
,
Menu
and
buttons in this order when the machine is in the
ready state. “MAINTENANCE 06” appears on the LCD.
(2) Press the
or
button to display the desired maintenance code on the LCD. Then
press the
OK
button.
To switch the machine back to the ready state, press the
Stop/Exit
button. When each of the
user-accessible functions is completed, the machine automatically returns to the ready state.
Memo:
• Operation using
Menu
,
*
,
2
,
8
,
6
and
4
buttons is also available.
Memo:
• To exit from the maintenance mode and switch to ready state, press the
9
button twice
in the initial state of the maintenance mode.
In the case of the model without the numeric keys; Press the
or
button. The
“MAINTENANCE 99” appears on the LCD. Then press the
OK
button, and the machine
returns to the ready state.
• When the
Stop/Exit
button is pressed, the machine beeps for one second and returns
to the initial state of the maintenance mode.
• When an incorrect maintenance mode is entered, the machine beeps for one second
and returns to the initial state of the maintenance mode.
Содержание DCP 7065DN
Страница 21: ...CHAPTER 1 SPECIFICATIONS ...
Страница 35: ...CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 44: ...2 7 Confidential ADF part Fig 2 5 Left Side Right Side Document feed path Face up ...
Страница 142: ...CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Страница 157: ...3 13 Confidential 4 New toner sensor PCB ASSY New toner sensor PCB ASSY Main PCB ASSY Guide ...
Страница 158: ...3 14 Confidential 5 T1 clutch ASSY REG clutch ASSY Main PCB ASSY REG clutch ASSY T1 clutch ASSY Guide Guide Guide ...
Страница 169: ...3 25 Confidential 21 Hook switch PCB Guide Main PCB ASSY Hook switch PCB Side cover L ...
Страница 183: ...3 39 Confidential 4 Remove the support flap 1 from the front cover ASSY Fig 3 20 Support flap 1 Front cover ASSY ...
Страница 194: ...3 50 Confidential 9 10 6 Gear Cover 1 Release the hook to remove the gear cover Fig 3 34 1a 1b Gear cover Hook ...
Страница 252: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 264: ...CHAPTER 5 SERVICE FUNCTIONS ...
Страница 271: ...5 5 Confidential Black and white scanning Fig 5 1 ...
Страница 311: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Страница 313: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High Voltage Power Supply PCB Circuit Diagram MURATA ...
Страница 314: ...6 2 Confidential High Voltage Power Supply PCB Circuit Diagram Panasonic ...
Страница 315: ...6 3 Confidential Low Voltage Power Supply PCB Circuit Diagram 115V EDPS 62AF A Delta ...
Страница 316: ...6 4 Confidential Low Voltage Power Supply PCB Circuit Diagram 115V MPW3058 MURATA ...
Страница 317: ...6 5 Confidential Low Voltage Power Supply PCB Circuit Diagram 230V EDPS 62BF A Delta ...
Страница 318: ...6 6 Confidential Low Voltage Power Supply PCB Circuit Diagram 230V MPW3059 MURATA ...
Страница 319: ...6 7 Confidential NCU PCB Circuit Diagram U S A Canada ...
Страница 320: ...6 8 Confidential NCU PCB Circuit Diagram Europe Oceania ...
Страница 321: ...6 9 Confidential NCU PCB Circuit Diagram China Asia Gulf ...
Страница 322: ...6 10 Confidential 2 WIRING DIAGRAM Wiring diagram ...
Страница 323: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Страница 324: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL REPLACEMENT PARTS 7 1 ...
Страница 325: ...7 1 Confidential 1 PERIODICAL REPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 326: ...APPENDIX 1 SERIAL NUMBERING SYSTEM Confidential ...
Страница 330: ...APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER Confidential ...
Страница 334: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...
Страница 336: ...APPENDIX 4 HOW TO MAKE PROTECTIVE MATERIAL OF DRUM UNIT Confidential ...