Programmer
161
Chapter 3 Programming with Command Function
Canceling thread breakage at the last stitch
Addition of feed after the last point can cancel thread
breakage at the last stitch.
When "115" is input for the end code, the thread breakage does not occur. In this case, every
thread breakage including emergency stop is canceled. Carry out the following setting for
canceling thread breakage at the specified point.
Programming
1.
Create the program 1 stitch (A) before the
desired end point.
2.
Press
and press
.
3.
Move the work clamp with
for the
stitch length. Press
when the needle point is
at point B of the pattern.
Point B is programmed.
4.
Press
.
5.
Move the work clamp with
. Press
when the needle point is at given point C.
Inputting the end code
1.
Press
and press
.
Содержание BAS-300F Series
Страница 7: ...6 Programmer Contents ...
Страница 8: ...Chapter 1 Preparations of operation ...
Страница 17: ...16 Programmer Chapter 1 Preparations of operation ...
Страница 18: ...Chapter 2 Programming with Help Function ...
Страница 85: ...84 Programmer Chapter 2 Programming with Help Function 4 Press Ending program 1 Press ...
Страница 120: ...Chapter 3 Programming with Command Function ...
Страница 195: ...194 Programmer Chapter 3 Programming with Command Function ...
Страница 196: ...Chapter 4 Extended Option Output BAS 300 Series ...
Страница 212: ...Chapter 5 Reading Writing Data ...
Страница 224: ...Chapter 6 Preference ...
Страница 226: ...Programmer 225 Chapter 6 Preference 5 After setting is complete press ...
Страница 227: ...226 Programmer Chapter 6 Preference ...
Страница 228: ...INSTRUCTION MANUAL BROTHER INDUSTRIES LTD NAGOYA JAPAN Printed in Japan 151 B11 S93B11 212 2002 12 WH 1 ...