3 - 14
Adjust
ment
Adjustment
Adjustment
Presser bar height
[Standard]
When the presser foot is raised, the clearance between the bottom surface of the presser
foot and the surface of the needle plate should be 5.5 to 6.75 mm.
[Adjustment]
1. Turn off the power, and then remove the foot controller.
2. Remove the face plate assy.
3. Attach the presser foot “J”.
4. Raise the presser foot lifter to raise the presser foot “J”.
5. Loosen the screw of the presser bar clamp.
6. Move the presser bar (presser foot) up and down, and adjust the clearance between the bottom surface of the
presser foot and the surface of the needle plate.
*Key point
• When measuring the height of the presser foot “J”, perform in the state that lower the feed dog than the
surface of the needle plate.
7. Tighten the screw of the presser bar clamp to secure the presser bar.
Screw, M3X8
Needle
plate
surface
Presser foot lifter
Presser foot “J”
5.5 - 6.75 mm
Presser bar
Screw
Presser bar clamp
Содержание 888X Series
Страница 2: ......
Страница 36: ...Basic of Disassembly 2 25 Feed unit Basic of Disassembly Basic of Disassembly Feed unit location diagram ...
Страница 67: ...5 1 5 Motor 3P supply assy 5 2 LED lead wire 5 3 Special Instructions of Wiring ...
Страница 70: ...43H15HF888X62 64 67 72 73 74 77 82 84 87 ...