2-90
Confidential
■
Error code CC
The fuser unit is not installed.
This error does not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
<User Check>
- Turn OFF the power switch, and turn it ON again after a while.
■
Error code CD
The drum unit is not installed.
<User Check>
- Check if the drum unit is installed into the machine.
No Fuser Unit
Install the Fuser Unit.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
No Drum Unit
Install the Drum unit.
Step
Cause
Remedy
1
Dirt on the electrode of the drum
unit and on the machine
Clean the dirt on the contact points of the
both electrodes.
(Refer to
and
2
Bend of electrode contact of
main body
Correct the bend of the electrode contact
of the main body.
3
Contact failure between the
electrode of the high-voltage
power supply PCB and that of
the machine
Clean the electrodes of the high-voltage
power supply PCB ASSY.
4
High-voltage power supply PCB
failure
Replace the high-voltage power supply
PCB ASSY.
5
Engine PCB failure
Replace the engine PCB ASSY.
Содержание 09055CDN
Страница 22: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Страница 37: ...Confidential CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 47: ...2 8 Confidential ADF part A4 model Fig 2 6 Left side Right side Document feed path Face up ...
Страница 48: ...2 9 Confidential ADF part Legal model Fig 2 7 Left side Right side Document feed path Face up ...
Страница 180: ...Confidential CHAPTER 3 DISASSEMBLY AND ASSEMBLY ...
Страница 211: ...3 28 Confidential 8 DISASSEMBLY FLOW Disassembly Re Assembly second ...
Страница 212: ...3 29 Confidential Disassembly Re Assembly second ...
Страница 306: ...3 123 Confidential 2 Remove the Rubber key R from the Panel cover Fig 3 170 Pin Pin Panel cover Rubber key R ...
Страница 358: ...3 175 Confidential 3 Remove the Filter ASSY from the Eject duct Fig 3 260 Eject duct Filter ASSY ...
Страница 394: ...3 211 Confidential 3 Disconnect the Connector from the Waste toner sensor Fig 3 323 Connector Waste toner sensor ...
Страница 416: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 436: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Страница 445: ...5 7 Confidential Black and white scanning First side Front Fig 5 1 ...
Страница 446: ...5 8 Confidential Black and white scanning Second side Back Fig 5 2 ...
Страница 447: ...5 9 Confidential Color scanning First side Front Fig 5 3 ...
Страница 448: ...5 10 Confidential Color scanning Second side Back Fig 5 4 ...
Страница 475: ...5 37 Confidential Cover page sample Fig 5 18 End page sample Fig 5 19 ...
Страница 482: ...5 44 Confidential Inter color position alignment adjustment chart Fig 5 23 ...
Страница 491: ...5 53 Confidential Color test pattern Fig 5 28 MCYK Y C K M YCMK_ _A ...
Страница 512: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Страница 514: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High voltage Power Supply PCB Circuit Diagram 1 3 ...
Страница 515: ...6 2 Confidential High voltage Power Supply PCB Circuit Diagram 2 3 ...
Страница 516: ...6 3 Confidential High voltage Power Supply PCB Circuit Diagram 3 3 ...
Страница 517: ...6 4 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Страница 518: ...6 5 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Страница 519: ...6 6 Confidential NCU PCB Circuit Diagram U S A Canada ...
Страница 520: ...6 7 Confidential NCU PCB Circuit Diagram Europe Oceania ...
Страница 521: ...6 8 Confidential NCU PCB Circuit Diagram China Asia South Africa Gulf ...
Страница 523: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Страница 581: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Страница 585: ...Confidential APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER ...
Страница 589: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...