background image

 
 

PHOENIX BF-BM4-LS

 Issue 1 

 

22 

 

 EC Declaration

 

 

DECLARATION OF PERFORMANCE 

 

ACCORDING TO DIRECTIVES 305/2011 (CONSTRUCTION  

PRODUCTS)  

 

  

  

 

 

ISSUED BY:

 

 

 

  

  

 

 

BROSELEY FIRES LTD 

                                 

KNIGHTS WAY, BATTLEFIELD ENT PARK.         

SHREWSBURY. SY1 3AB ph: +44 (0)1743 461444

 

 

 

 

 

 

 

 

 

  

TYPE OF EQUIPMENT: 

 

 

 

WOOD BURNING STOVE

 

 

 

 

 

 

 

 

 

  

TRADEMARK:

 

 

 

BROSELEY FIRES LTD                                   

 

 

 

 

 

 

 

 

MODEL:

 

  

PHOENIX BF-BM4-LS 

 

 

 

 

 

 

 

 

USE:

 

  

DOMESTIC SPACE HEATING

 

 

 

  

  

  

  

  

  

 

 

 

 

  

 

 

MANUFACTURER:

 

 

 

  

  

 

 

BROSELEY FIRES LTD 

                                 

KNIGHTS WAY, BATTLEFIELD ENT PARK.         

SHREWSBURY. SY1 3AB ph: +44 (0)1743 461444

 

  

  

  

  

  

  

  

  

  

  

 

 

RRF Rhein-Ruhr Feuerstätten Prüfstelle GmbH 

NOTIFIED BODY: 

RRF 1625    

  

  

 

 

Firmensitz 

Im Lipperfeld 34 b  

D-46047 Oberhausen  

 

 

 

 

 

 

 

 

The following  harmonised standards and Technical specifications have been met and  comply 
with good engineering practice and safety matters in force within the EEC

 

 

 

 

 

 

 

 

 

All CE standards or other documents 

   Innitial Type Test Reports         RRF-40 14 3630   

  

  

  

 

 

  

  

                

 

 

 

 

 

 

 

 

 

 

 

EN 13240

 

 

 

CE MARKING INFORMATION  

-  

See Specifications

 

 

 

 

 

 

 

 

 

                                     AVCP

 

System 3  

  

  

 

 

 

 

 

 

 

 

As the Manufacturer's authorised representative established within the EEC, Broseley Fires Ltd 
Declare sole responsibility  that the product for mentioned follows the provisions of the directives 
above.

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

13/11/2013  Shrewsbury UK 

 

STEPHEN GOODWIN

 

 

    Place and date of issue

 

 

Head of Research & Development

 

 

Содержание Phoenix 8

Страница 1: ...BM4 LS Issue 1 1 Installation Operating Instructions Covering Model Phoenix 8 BF BM4 LS Wood Burning Stove Tested to EN 13240 These appliances must be installed and commissioned by a HETAS registered...

Страница 2: ...ion Controls Layout 12 Controls Explained 13 Air wash System 13 Ash Pan 13 Recommended Fuels 14 Lighting the Stove Kindling Stage 15 Burning Wood 16 Warning Notes 17 Maintenance Ash Removal 18 Chimney...

Страница 3: ...te conditions In all cases the installation must comply with current Building Regulations Local Authority By laws and other specifications or regulations as they affect the installation of the stove I...

Страница 4: ...should be taken to avoid the possibility of personal injury CO Alarms Building regulations require that whenever a new or replacement fixed solid fuel or wood biomass appliance is installed in a dwel...

Страница 5: ...t is designed and tested for intermittent use European standards need to be complied with when installing this appliance Phoenix BF BM4 LS Nominal Heat Output Wood to Room kW 8 Efficiency 84 Weight Kg...

Страница 6: ...PHOENIX BF BM4 LS Issue 1 6 Dimensions ALL DIMENSIONS ARE IN MILIMETRES...

Страница 7: ...f the stove to carpets or wooden floors must be at least 300mm As it is possible that on opening the door of the stove for fuel to fall out a fender must be fitted if the hearth is flush with the carp...

Страница 8: ...e top of the chimney e g anti down draft cowl to eliminate wind induced down draft The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Re...

Страница 9: ...a fixed permanent air vent see Building Regulations Approved Document J for further information Calculating the vent For new build you will need to provide 8 x 550mm2 4400mm2 free air Older propertie...

Страница 10: ...X BF BM4 LS Issue 1 10 Assembly The diagram below shows the stove with all internals taken out To install these parts follow the numbered sequence above to un install simply follow the sequence in rev...

Страница 11: ...and commissioning ensure that the operating instructions for the stove are left with the consumer Ensure to advise the customer on the correct use of the appliance and warn them to use only the recom...

Страница 12: ...needs to be operated correctly to control the combustion rate of the stove Sliding the control fully to the left indicates that the air intake is fully open whilst sliding it fully to the right indica...

Страница 13: ...ystem Air wash is a system where air is drawn into the stove by combustion through the air intake and is deflected down the inside face of the glass thus preventing the smoke coming into contact with...

Страница 14: ...t the stove and flue The coating of soot and tar in the chimney is volatile creating a high risk of chimney fires A growing tree contains a high percentage of water the wood needs to be dried out seas...

Страница 15: ...dry kindling onto the newspaper ensure their is sufficient air gaps between the kindling a criss cross or pyramid style pattern is ideal to accomplish this Kindling Newspaper Stage 2 Ignite the paper...

Страница 16: ...y in the middle You will now control the burn rate of the stove using the air control You are looking for a controlled flame not smouldering in the embers or licking around the lid this is mostly visu...

Страница 17: ...CAUSED THROUGH OVER FIRING WILL NOT BE COVERED BY THE WARRANTY Fumes Properly installed operated and maintained this stove will not emit fumes into the dwelling Occasional fumes from de ashing and re...

Страница 18: ...e served an open fire previously it is possible that the higher flue gas temperature from a closed appliance may loosen deposits that were previously firmly adhered with the consequent risk of flue bl...

Страница 19: ...chimney to prevent heat being drawn up the chimney to waste Green or wet wood is being burnt The chimney has excessive draw this is unusual Seek installer advice with regard to installing a Flue Draug...

Страница 20: ...______________________ Address _________________________________________________________________ Telephone Inc area code ____________________________________________________ HETAS Registration Number...

Страница 21: ...ndle 10 Airwash Plate 11 Ash pan 12 Ash Deflector 13 Lower Door Hinge 14 Sprint Locator 15 Door Spring 16 Grate 17 Upper Door Hinge 18 Primary Air Slider 19 Secondary Air Slider 20 Air Control Plate 2...

Страница 22: ...elle GmbH NOTIFIED BODY RRF 1625 Firmensitz Im Lipperfeld 34 b D 46047 Oberhausen The following harmonised standards and Technical specifications have been met and comply with good engineering practic...

Страница 23: ...COMPANY NAME COMPANY ADDRESS POSTCODE 3RD YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 4TH YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NA...

Страница 24: ...d units Replaced parts or components will become the property of Broseley Fires Should you wish to claim under the warranty please contact the supplier dealer from whom you purchased the appliance Do...

Отзывы: