Assembly – Smoke Control Area Specification
Your appliance will be delivered ready to be installed into a smoke control area. The
appliance has a permanent mechanical stop on the secondary (wood) air supply (this
ensures that the air intake cannot close completely). This mechanical stop cannot be
modified.
Assembly – Internal Components
The diagram below shows the stove with all internals taken out. To take internals out of
the stove follow the numbered sequence backwards from 10 down to 1.
1. Top Rear Vermiculite
– Replace by removing Tertiary air bar (2)
2. Tertiary Air Bar
– Remove by Loosening 10mm bolts
3. Bottom Rear Vermiculite
4. Right Side Vermiculite
5. Left Side Vermiculite
6. Baffle
– Remove by pulling towards the front of stove and drop on one side
7. Grate
8. Base Rear Vermiculite
9. Base Side Vermiculite
10. Log retainer
11. Ash Pan
– Not required to be removed if replacing internals.
1.
To refit the internals follow the numbered sequence from 1
– 11.