Pressure Testing
Test the operating pressure of the appliance by attaching a pressure gauge to the test
point of the pressure test elbow. This connection should be made when the appliance is
OFF. Ensure that gas is turned on at the gas meter and purge the air from the appliance
by following the instructions below.
Push Button Electronic Igniter Pressure test point
Control Valve Knob
(un-screw to access battery)
Rotating the control valve knob to the
(IGN) position
and push the Push igniter button
(red button located bottom left) the pilot should light. If the appliance does not light after
10 seconds the knob should be rotated back to the
(OFF) position and then back to
the
(IGN) position to generate the spark at the electrode. Check that the spark is
being generated correctly at the pilot assembly. Continue with this procedure until the air
is purged from the appliance and the pilot is lit. Once lit, hold the control knob in for up to
10 seconds. Once the pilot is established, turn the control knob anti-clockwise to the
🔥
(HIGH) position. Allow the appliance to run for a minimum of 5 minutes. Next check that
the inlet pressure to the appliance is at 20 mbar (+/- I mbar).
Please note the flames will appear blue until the appliance reaches temperature. This can
take between 10 and 20 minutes.
If the appliance is extinguished or goes out, wait 3 minutes before attempting to re-light.
Please note the battery for the push button ignitor is located directly behind the button
itself, it can be accessed by un-screwing the button in an anti-clockwise direction. The
ignitor uses a single AA battery which will periodically need to be replaced
Please note during the initial firings of the appliance it will emit a
strong odour, this is normal and part of the paint curing process and
will reduce with repeated use.